Model |
KRYP-15W KRYP-15 |
KRYP-25W KRYP-25 |
KRYP-38W |
KRYP-60W |
||
Temp Range |
-40℃~135℃ |
-40℃~135℃ |
-40℃~135℃ |
-40℃~135℃ |
||
Tank volume |
60L |
100L |
200L |
300L |
||
heating power |
15kw |
25kw |
38kw |
60kw |
||
make cold measure |
135℃ |
15kw |
25kw |
38KW |
60kw |
|
20℃ |
15kw |
25kw |
38KW |
60kw |
||
0℃ |
15kw |
25kw |
38KW |
60kw |
||
-20℃ |
10kw |
16kw |
26KW |
37kw |
||
-35℃ |
4kw |
6.5kw |
10KW |
15kw |
||
Temperature Control Accuracy |
±0.3℃ |
|||||
System pressure display |
Pressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure); The circulation system pressure is displayed on the touch screen by pressure sensor detection. |
|||||
Controler |
Siemens PLC and Fuzzy-PID Control Algorithm |
|||||
Communicating Protocol |
Ethernet Interface TCP/IP Protocol |
|||||
Internal Temp Feedback |
Equipment tank internal temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured)。 |
|||||
Heat |
The maximum heating output power of the system (according to each model); The heater has triple protection and independent temperature limiter to ensure the safety of heating system; Heating power 10KW adopts regulator, heating power output control adopts 4~20mA linear control. |
|||||
Refrigerating Capacity |
Refers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures. |
|||||
High temperature cooling module |
It is possible to cool the module from a high temperature of 150℃ |
|||||
Circulating pump flow Max |
Adopt crown submagnetic drive pump / German brand magnetic drive pump |
|||||
110L/MIN 2.5BAR |
150L/MIN 2.5BAR
|
200L/MIN 2.5BAR |
300L/MIN 2.5BAR |
|||
Source 380V50HZ |
24KW max |
38KW max |
58kw max |
95kw max |
||
Shape Size (Air-cooled) |
800*1200*1850 |
1000*1500*1850 |
|
|
||
Shape Size (Water cooled) |
800*1200*1850 |
1000*1500*1850 |
1000*1500*1850 |
1450*2050*2050 |
||
Compression Engine |
Emerson Valley Wheel / Turin, Italy |
|||||
Evaporimeter |
Adopting DANFOSS Plate Heat Exchanger / High strength Plate Heat Exchanger |
|||||
Refrigeration Accessory |
Emerson / Danfoss brand dry filter, pressure control, oil separator, etc. |
|||||
Expansion Valve |
Danfoss thermostatic expansion valve/ Emerson electronic expansion valve |
|||||
Operation Panel |
7-inch color touch screen, and the temperature curve shows the export of EXCEL data |
|||||
Safe Guarding |
With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. |
|||||
Cryogen |
R-404A/R507C |
|||||
Electronic pump interface |
DN50 PN10 RF |
DN65 PN10 RF |
DN80 PN10 RF |
DN100 PN10 RF |
||
Water-cooled type W |
Type W is water cooled |
|||||
Water-cooled Condenser |
Double-pipe (heat) exchanger |
|||||
Cooling Water 32℃ |
7m³/H |
12m³/H |
17m³/H |
24m³/H |
||
Shell material |
Cold rolled sheet spray (Standard Colour 7035) |
|||||
Temperature spread |
-40℃~150℃ |