Tips for shutting down the industrial chiller for temperature control of the reactor
Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to master the actual use needs. The method of shutting down the industrial chiller to reduce problems such as excessive wear and tear of the equipment.
Method for shutting down the industrial chiller of the reactor temperature control unit:
1. When the chiller for industrial reactor needs to be shut down, it is necessary to first consider the shutdown range of the chiller before all shutdown operations can be performed. In order to avoid generating a large pressure, the user needs to close the suction shut-off valve to stop the operation of the compressor.
2. After closing the chiller compressor, it is necessary to operate the oil pump. Return the slide valve of the industrial single-reactor chiller to the 0-scale position, so that the load reduction reaches zero, and the oil pump will immediately stop all operations.
3. The chiller is used for a single industrial reactor, and the operation of the water pump and the cooling water tower needs to be stopped in the latter step. After such equipment is stopped, the entire power supply of the industrial single reactor freezer can be turned off, and the entire shutdown process of the industrial ice water machine can be completed. Ensure that the industrial chiller for a single reactor is in a shutdown state.
Precautions:
1. If the machine is shut down for a long time, it is necessary to carry out special treatment for the industrial single reactor chiller. Including the condenser and the evaporator, it is necessary to completely pump the refrigerant to the condenser, and at the same time discharge all the water sources to avoid problems such as corrosion.
2. After the shutdown is completed, it is necessary to carry out detailed inspections for various accessories. The shutdown process is more particular, and the use of the shutdown steps can prolong the service life of the equipment.
Fassen Sie zusammen:
For the chiller for industrial single reactor that has been shut down for a long time, it is necessary to carry out careful testing to ensure that the equipment is kept away from various corrosive substances, and to improve the shutdown performance of the chiller for industrial single reactor.
Verwandte Empfehlungen
-
Die Rolle der Kältemaschine im Herstellungsprozess von katalytischen Materialien
1609In the field of new material preparation, by accurately controlling the reaction temperature, the influence of different temperatures on the microstructure and macroscopic properties of materials can be explored, thereby developing new mat...
Details anzeigen -
Durch Öldruck verursachter Ausfall des Verdichters des Kältesteuersystems
1580Wenn im Kühlsystem kein Öldruck vorhanden ist, überprüfen Sie den Anschluss des Ölpumpen-Rohrsystems auf Ölleckagen oder Verstopfungen. Wenn die Verbindung locker ist, sollte sie angezogen werden. Wenn sie blockiert ist, sollte die Ölleitung frei gemacht werden...
Details anzeigen -
The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
2040Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system...
Details anzeigen -
Welche Art von Temperaturkontrollsystem ist für die Abstrichvorbereitung in der pharmazeutischen Industrie erforderlich?
1418In der pharmazeutischen Industrie stellen Unterdrucktrocknung und Abstrichvorbereitung besondere Anforderungen an die Temperaturkontrolle und erfordern in der Regel präzise und einstellbare Temperaturkontrollgeräte, um die Produktqualität und die Prozessstabilität zu...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant