Industrielle Schraubenkühler der LG-Serie
ANWENDUNGEN
Applicable to various chemical, pharmaceutical, mechanical and other fields as process cooling sources, can provide -110℃~30℃ refrigeration medium, can be used as ice storage, low temperature air supply and other process cooling sources required by production processes.
Produktmerkmale
Produkt-Parameter
This series of screw chillers has a total of 6 temperature sections to choose from, all of which are water-cooled.
| Modell | LG1-75W | LG1-100W | LG1-140W | LG1-180W | LG1-230W | LG1-280W | |
| Temperaturbereich | 5℃~30℃ | ||||||
| Kühlleistung 7℃ |
kW | 236 | 328 | 468 | 608 | 762 | 936 |
| Kcal/hr*10³ | 202.9 | 282.1 | 402.5 | 522.9 | 655.3 | 805.0 | |
| Leistung | 3N/400V/50HZ | ||||||
| Kühlleistungsaufnahme bei (7℃) | 64 | 84 | 120 | 155 | 191 | 236 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 40 | 56 | 80 | 104 | 131 | 160 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN80 | DN100 | DN125 | DN150 | |||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 51 | 71 | 101 | 131 | 163 | 201 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN80 | DN100 | DN150 | DN200 | |||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| RefrigerantR404A | Charge Kg | 49 | 56 | 69 | 115 | 133 | 180 |
| Dimension | Length cm | 313 | 314 | 314 | 328 | 330 | 340 |
| Width cm | 110 | 110 | 110 | 110 | 110 | 110 | |
| Height cm | 157 | 178 | 180 | 202 | 207 | 220 | |
| Gewicht pro Einheit | 1740 | 2480 | 2870 | 3400 | 3600 | 4050 | |
| Working weight | 1890 | 2580 | 3120 | 3700 | 3900 | 4350 | |
Security device:High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload
protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc
| Modell | LG2-75W | LG2-100W | LG2-140W | LG2-180W | LG2-230W | LG2-280W | |
| Temperaturbereich | -25℃~5℃ | ||||||
| Kühlleistung -20℃ |
kW | 80 | 111 | 158 | 206 | 259 | 318 |
| Kcal/hr*10³ | 68.8 | 95.5 | 135.9 | 177.2 | 222.7 | 273.5 | |
| Leistung | 3N/400V/50HZ | ||||||
| Cooling input power at (-20℃) | 56 | 74 | 105 | 136 | 166 | 205 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 24 | 32 | 46 | 59 | 75 | 92 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN65 | DN80 | DN100 | DN125 | |||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 26 | 35 | 50 | 65 | 80 | 99 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN80 | DN100 | DN125 | DN150 | |||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| RefrigerantR404A | Charge Kg | 60 | 81 | 113 | 146 | 184 | 222 |
| Dimension | Length cm | 300 | 310 | 320 | 330 | 340 | 350 |
| Width cm | 160 | 160 | 170 | 180 | 180 | 180 | |
| Height cm | 225 | 225 | 235 | 235 | 245 | 245 | |
| Gewicht pro Einheit | 2400 | 2600 | 2700 | 2800 | 3000 | 3100 | |
| Working weight | 2550 | 2750 | 2850 | 2950 | 3150 | 3250 | |
| Modell | LG4-75W | LG4-100W | LG4-140W | LG4-180W | LG4-230W | LG4-280W | |
| Temperaturbereich | -45℃~-10℃ | ||||||
| Kühlleistung -40℃ |
kW | 50 | 70 | 95 | 120 | 155 | 180 |
| Kcal/hr*10³ | 43 | 60.2 | 81.7 | 103.2 | 133.3 | 154.8 | |
| Leistung | 3N/400V/50HZ | ||||||
| Cooling input power at (-40℃) | 35 | 48 | 65 | 82 | 106 | 113 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 23 | 32 | 44 | 56 | 72 | 83 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN65 | DN80 | DN100 | DN125 | |||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 16 | 20 | 30 | 36 | 46 | 60 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN65 | DN80 | DN100 | DN125 | |||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| RefrigerantR404A | Charge Kg | 65 | 87 | 122 | 158 | 199 | 240 |
| Dimension | Length cm | 380 | 420 | 430 | 480 | 500 | 520 |
| Width cm | 160 | 180 | 220 | 230 | 340 | 450 | |
| Height cm | 225 | 225 | 235 | 235 | 245 | 245 | |
| Gewicht pro Einheit | 4200 | 4300 | 4400 | 4500 | 4600 | 4700 | |
| Working weight | 4350 | 4450 | 4550 | 4650 | 4750 | 4850 | |
| Modell | LG6-75 | LG6-100W | LG6-140W | LG6-180W | LG6-230W | LG6-280W | |
| Temperaturbereich | -60℃~-10℃ | ||||||
| Kühlleistung -55℃ |
kW | 66 | 87 | 121 | 158 | 202 | 238 |
| Kcal/hr*10³ | 56.7 | 74.8 | 104.0 | 135.8 | 173.7 | 204.6 | |
| Leistung | 3N/400V/50HZ | ||||||
| Kühleingangsleistung bei (-55℃) | 103 | 135 | 192 | 249 | 310 | 375 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 34 | 45 | 63 | 82 | 105 | 123 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN80 | DN100 | DN125 | ||||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 26 | 34 | 48 | 62 | 79 | 94 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN80 | DN100 | DN125 | DN150 | |||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| RefrigerantR404A/R23 | Charge Kg | 29/22 | 38/29 | 53/41 | 69/54 | 89/69 | 105/82 |
| Dimension | Length cm | 420 | 420 | 450 | 450 | 450 | 450 |
| Width cm | 200 | 210 | 220 | 225 | 230 | 235 | |
| Height cm | 237 | 240 | 245 | 250 | 255 | 255 | |
| Gewicht pro Einheit | 4800 | 4900 | 5000 | 5100 | 5200 | 5300 | |
| Working weight | 4950 | 5050 | 5150 | 5250 | 5350 | 5450 | |
| Modell | LG8-75W | LG8-100W | LG8-140W | LG8-180W | LG8-230W | LG8-280W | |
| Temperaturbereich | -80℃~-30℃ | ||||||
| Kühlleistung -75℃ |
kW | 36 | 48 | 67 | 88 | 112 | 131 |
| Kcal/hr*10³ | 30.9 | 41.3 | 54.2 | 72.2 | 96.3 | 112..3 | |
| Leistung | 3N/400V/50HZ | ||||||
| Cooling input power at (-75℃) | 83 | 110 | 156 | 203 | 254 | 308 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 22 | 30 | 36 | 55 | 70 | 82 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN65 | DN80 | DN100 | ||||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 18 | 23 | 31 | 43 | 54 | 65 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN65 | DN80 | DN100 | DN125 | |||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| RefrigerantR404A/R508B | Charge Kg | 26/20 | 34/26 | 48/35 | 61/47 | 80/62 | 94/74 |
| Dimension | Length cm | 420 | 420 | 450 | 450 | 450 | 450 |
| Width cm | 200 | 210 | 220 | 225 | 230 | 235 | |
| Height cm | 237 | 240 | 245 | 250 | 255 | 255 | |
| Gewicht pro Einheit | 4800 | 4900 | 5000 | 5100 | 5200 | 5300 | |
| Working weight | 4950 | 5050 | 5150 | 5250 | 5350 | 5450 | |
| Modell | LG11-75W | LG11-100W | LG11-140W | LG11-180W | LG11-230W | LG11-280W | |
| Temperaturbereich | -110°C~ -50°C | ||||||
| Kühlleistung -105℃ |
kW | 9 | 12 | 16 | 22 | 28 | 32 |
| Kcal/hr*10³ | 7.7 | 10.3 | 13.8 | 18.9 | 24.1 | 27.5 | |
| Leistung | 3N/400V/50HZ | ||||||
| Kühlleistungsaufnahme bei (-105℃) | 56 | 75 | 105 | 135 | 172 | 210 | |
| Kompressor | Formular | Halbgeschlossener Doppel-Schrauben-Kompressor | |||||
| Temperaturregelbereich | 25%~100% | ||||||
| Kühlwasser | Formular | Platten-, Trocknungs-, Überlauf- oder Fallfilm-Wärmetauscher | |||||
| Kühlwasser-Menge T/H | 3 | 4 | 5 | 7 | 8 | 10 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN40 | DN50 | DN65 | ||||
| Kühlwasser | Formular | Horizontaler Rohrwärmetauscher | |||||
| Kühlwassermenge T/H | 8 | 10 | 14 | 19 | 24 | 27 | |
| Wasserdruckverlust | 40~80 | ||||||
| Größe der Verbindung | DN50 | DN65 | DN80 | ||||
| Security device | High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc |
||||||
| Kältemittel | R14/R23/R404A | ||||||
| Dimension | Length cm | 250 | 300 | 350 | 400 | 450 | 500 |
| Width cm | 145 | 160 | 160 | 160 | 200 | 220 | |
| Height cm | 225 | 225 | 245 | 245 | 260 | 265 | |
| Gewicht pro Einheit | 2200 | 3000 | 3500 | 4000 | 4500 | 5000 | |
| Working weight | 2350 | 3150 | 3650 | 4150 | 4650 | 5150 | |
Nehmen Sie Kontakt mit unseren Experten für Reaktorkühlmaschinen auf
Sie können keinen geeigneten Kühler finden? Oder wissen Sie nicht, wie Sie eine Kältemaschine auswählen sollen? Kontaktieren Sie uns jetzt, um Details und Preise für Kühlgeräte zu erhalten.
Kontaktieren Sie uns
Senden Sie uns Ihre Anfrage und wir werden Sie innerhalb von 24 Stunden kontaktieren
Serie mit variabler Frequenz spart 20 % mehr Energie als Serie mit fester Frequenz
Mindestbestellmenge: 1, 1 Einheit ist auch Großhandelspreis.

Ihr Hersteller von Qualitätskältemaschinen
lneya verwendet zuverlässiges Materialzubehör internationaler Marken, Siemens-SteuerungenTaikang-Kompressoren, usw. Sie können von unseren Kältemaschinen erwarten, dass sie präzise Temperaturregelung und die besten Ergebnisse.
Warum sollten Sie sich für lneya als Ihren Lieferanten für Temperaturkontrolle entscheiden?
Jahre der Erfahrung
Zufriedene Kunden
m² Produktionsfläche
Patentierte Technologien
Besuch der LNEYA-Fabrik
Produkte empfehlen
LNEYA Industriekühler Hersteller Lieferant