FL-WS 5℃~30℃
Hochleistungskühler- Kühlung Leistung89kW~1724kW
- Stromversorgung3N/380V/50Hz
- Gewicht850kG~7900kG
Produktdaten herunterladen
Beschreibung des Produkts
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
(2) Aufgrund der ständigen Aktualisierung der Produkttechnologie können die oben genannten Daten ohne vorherige Ankündigung geändert werden.
3. zusätzlich zu den aufgelisteten Produktmodellen kann unser Unternehmen auch Nicht-Standard-Geräte nach Kundenwünschen anpassen.

This series of equipment is suitable for various production process cold sources in the fields of chemical industry, medicine, machinery, etc. It can provide -110℃~30℃ refrigeration medium, and can be used as ice storage, low-temperature air supply and other process cold sources required by production processes. Our company can specially design the unit according to the requirements of users. The unit adopts advanced semi-enclosed screw compressor, which is low-carbon, energy-saving and environmentally friendly; it has good performance and low noise, and can run without trouble for more than 100,000 hours; the temperature control can be step-by-step energy regulation or stepless energy regulation control. According to the heat load required by the specific production, the outlet water temperature of the refrigerant is used as the control point, and the control center sends instructions to adjust the movement of the energy regulation slide valve to adjust the load of the compressor unit to achieve a real energy-saving effect.
| Model FL- | 100WS | 200WS | 300WS | 400WS | 510WS | 660WS | 1700WD | |
| Kühlleistung 5℃ |
kW | 103 | 203 | 280 | 370 | 506 | 678 | 1724 |
| Kcal/hr*10³ | 89 | 175 | 241 | 318 | 435 | 583 | 1483 | |
| ±0.5 | ||||||||
| Stromversorgung | 3N/380V/50HZ | |||||||
| Cooling input power | 23 | 46 | 62 | 81 | 110 | 146 | 362 | |
| Kompressor | Formular | Halbhermetischer Schraubenverdichter | ||||||
| Bereich der Energiekontrolle | 0~25~37.5~50~62.5~75~87.5~100(12.5% segment control) | |||||||
| Chilled Water | Formular | Dry, flooded or falling film heat exchangers | ||||||
| Chilled water volume T/H | 20 | 35 | 50 | 65 | 86 | 115 | 280 | |
| Water pressure drop KPa | 40~80 | |||||||
| Take over specifications | DN65 | DN100 | DN125 | |||||
| Kühlwasser | Formular | Horizontal shell and tube | ||||||
| Cooling water volume T/H | 22 | 45 | 60 | 80 | 110 | 140 | 360 | |
| Water pressure drop KPa | 40~80 | |||||||
| Take over specifications | DN65 | DN100 | DN125 | |||||
| Protective Device | High and low voltage protection, anti-icing, heat release protection, safety valve, overload protection, phase loss, reverse phase, undervoltage, overvoltage, water flow protection, etc. | |||||||
| Kältemittel | Filling amount Kg | 22 | 44 | 55 | 58 | 80 | 115 | 235 |
| Abmessungen | Length mm | 250 | 264 | 313 | 314 | 314 | 328 | 397 |
| Width mm | 85 | 90 | 110 | 110 | 110 | 110 | 160 | |
| High mm | 130 | 143 | 157 | 178 | 180 | 202 | 225 | |
| Gewicht | 850 | 1270 | 1740 | 2480 | 2870 | 3400 | 7900 | |
| Operating Weight | 900 | 1420 | 1890 | 2580 | 3120 | 3700 | 8600 | |
Vielleicht interessieren Sie sich auch für diese Produkte
LT -45℃~30℃
LOW TEMPERATURE COOLING CIRCULATOR For fast liquid cooling 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Circulating pipeline design, prolong t…
LT 10℃~30℃
Einsparung von Wasserressourcen & zirkulierende Kühlung 1. Kann Ethylenglykol gemischt mit Wasser für zirkulierende Kühlung verwenden, spart Ressourcen 2.Circulating Pipeline Design, verlängern die Nutzungszeit von zirkulierenden ...
LT -25℃~30℃
Schnelle Kühlung mit importierten Marke halbgeschlossenen Kolbenkompressor, halbgeschlossenen Kolben zweistufigen Kompressor, halbgeschlossenen Schraubenverdichter 1. Kann Ethylenglykol gemischt verwenden ...
loading…
已经是到最后一篇内容了!