Cooling system of liquid-cooled energy storage cabinet-chiller
With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well controlled, the temperature of the battery will be unstable, leading to an increased risk of short circuit and damage to surrounding components.
The containerized energy storage system is mainly composed of a containerized machine room, a battery management system, and a battery pack temperature control system. Therefore, the cooling system of the special containerized energy storage system is becoming more and more high-performance and highly stable. The temperature control system includes chillers, chiller pipes, air conditioners, and air ducts. Provide suitable and stable ambient temperature for the overall container energy storage system.
During the work of the containerized energy storage system, the lithium battery system, battery management system, energy storage monitoring and other systems will generate a lot of heat due to current changes. In order to ensure the efficient operation of the energy storage system at all times, some systems will be equipped with dedicated energy storage system cooling units , The cooling method is divided into two types: air-cooled and water-cooled.
LNEYA’s energy storage integrated cabinet cooling system follows a compact design and can be an external cooling system for the battery pack energy storage integrated cabinet. Efficient nanny-style thermal management system is suitable for applications where the battery inside the energy storage container generates a lot of heat and is sensitive to ambient temperature. Integrate upper computer communication, alarm and other functions, without complicated debugging.
Liquid cooling is integrated into each battery cabinet using glycol antifreeze. The system is fully enclosed design, supports dual system cooling circuits, mutual backup to avoid battery shutdown and safety failure; intelligent, multi-language color touch screen, provides clear and comprehensive important data information, and can display flow pressure data in real time; liquid cooling system IP50 The above protection can meet the anti-corrosion requirements, and can be used below 3000 meters above sea level. The temperature setting range is -45°C~55°C, and the liquid temperature can be precisely controlled within ±0.5°C.


Verwandte Empfehlungen
-
Flüssigkühler(Beladungsstapel)
2255Modell CHDYL-4 -45℃~55℃ Kühlleistung 4KW Temperaturregelgenauigkeit ±1℃ Echtzeit-Temperaturaufzeichnung Kältemittel Solezirkulationssystem vollständig geschlossenes Design Durchfluss 1.8~5.5L/min Druck 0.7bar Minimale Wassereintrittstemperatur 15°C ...
Details anzeigen -
Flüssigkeitskühler(Energiespeicher)
3184Model CNYL -45~55 Cooling Capacity 45KW Temperature Control Accuracy ±0.5℃ Real-time temperature record Secondary Refrigerant Ethylene glycol antifreeze, fully enclosed design of refrigerant circulation system Refrigerant R41...
Details anzeigen -
Flüssigkeitskühler(Gewerbliche Energiespeicherung)
2328Battery Energy Storage Systems are filled with many battery cells, generating a large amount of extreme heat load. This means that the cooling system needs to precisely control the temperature and efficiently dissipate the l...
Details anzeigen -
Feiern Sie den Neujahrstag und begrüßen Sie das neue Jahr
1280When the bells echo in the clear night sky,When the calendar turns to a new page,We are about to usher in a new year.Thanks for this year's harvestLet us have precious experience on our growthThere is always a reward for sweatThis yearWe sh...
Details anzeigen -
Refrigerating Output of Low Temperature Cooling Circulator
888The refrigerating output of low temperature cooling circulator varies with different working conditions. So, when the process calculation is carried out at the beginning, it is necessary to set an allowance for the refrigerating output of the heat...
Details anzeigen -
Entwicklungsperspektive einer Temperaturmess- und -regelvorrichtung für ein mikrofluidisches Chip-System
1348Mit der kontinuierlichen Entwicklung von Chinas Wissenschaft und Technologie hat es große Fortschritte im Bereich der integrierten Schaltungen und Chips gegeben. Die Geräte zur Temperaturmessung und -regelung im LNEYA-Mikrofluidik-Chip-System haben ...
Details anzeigen -