Wie geht man mit einer Störung des industriellen Kaltwassersatzes um?
What’s wrong with the Industrial Water Chiller System when it fails to cool down?
Let LNEYA explain it to you below:
One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with the installation of water-cooled chiller, cooling water tower, circulating water pump and pipe. It needs to be carefully checked according to the installation diagram.
The second reason may due to the pipes which are attached to various devices for a long time, and the impurities have accumulated in the water sources, resulting in smaller water flow. Therefore, we must clean the pipes between the devices.
Thirdly, If this problem occurs during the first use, it may cause by the wrong matching of the chiller and the problem of delivery. Because the industrial chiller has carried out 100% performance tests before getting out of the machine to ensure the normal operation of the machine unit.
Finally, If this is the case of a chiller that has been used for half a year or 1-2 years later, it may due to the leakage of Freon in the cooling system of the cold water machine. It is suggested to find out the leakage, weld it again and refrigerant. The heat exchanger of the water-cooled chiller is dirty and needs washing, and remember to clean it regularly after subsequent use.
The operation of any Industrial Water Chiller System is inseparable from the participation of refrigerant. So the shortage of refrigerant will affect the normal operation of the industrial chiller, and then result in the reduction of refrigerating capacity of the industrial chiller and even shut down, which is also the main reason for the shrinkage of the refrigerating capacity of the industrial chiller.

Verwandte Empfehlungen
-
Vorsichtsmaßnahmen bei der Verwendung von chemischen Kühl- und Heizkreislaufsystemen
1024Bei der chemischen Produktion wird durch die Reaktion Wärme erzeugt, die zu einer ungleichmäßigen Wärmeentwicklung führt. Wird sie nicht rechtzeitig abgeleitet, erhöht sich die Temperatur im Kessel und es besteht Gefahr. Das bestehende Heizsystem des Reaktors ist relati...
Details anzeigen -
Fliege durch Traum, schaffe größeren Ruhm, [Wuxi Guanya LNEYA] Jahresfeier erfolgreich beendet
1458Inadvertently2019 has passedThis yearThanks to everyone for the trust and support of Guanya LNEYA Eye-catching gloryFrom every step of the solidThank you all the wayDream-seeking career2020 Let us continue to work together for a win-win sit...
Details anzeigen -
The role of temperature control system TCU in chemical and pharmaceutical reactor
1273The temperature control of the reaction kettle in drug research and development and chemical experiments, as well as the temperature control in small-scale experimental production and industrial production processes, require highly dynamic tempera...
Details anzeigen -
About the size and installation height of refrigeration heating temperature control system equipment
848Whether it is biopharmaceutical, traditional Chinese medicine or chemical pharmacy, pharmaceutical companies are all related to chemistry, because the extraction and synthesis of pharmaceutical ingredients are all in the form of chemical products...
Details anzeigen