Wartung einer Vakuumpumpe für eine vollständig geschlossene Heizungs- und Kühlungsumwälzanlage
Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump?
For the fully enclosed heating and cooling circulator circuit, the electronic circuit and the mechanical rotating part are routinely inspected and repaired. Pay attention to whether the various indicators are damaged or deteriorated, and regular maintenance is required.
Do the vacuum pump working status and the registration of each working time, record the cause of the instrument failure and the troubleshooting method in time to ensure that the vacuum pump works in a better state.
Keep the vacuum pump symmetrically balanced. If the sample tube placed in the pump chamber is unbalanced, it will cause the circulating water vacuum pump to shift. After the shutdown is reset, check if the vacuum pump is normal.
Before use, please pay attention to check the rotor for corrosion points and fine cracks. The rotor that has been corroded or cracked is forbidden to use. If the rotor exceeds the shelf life, it should be checked frequently to ensure personal safety.
The fully enclosed heating and cooling circulator vacuum pump cover door bolts should be checked frequently and kept flexible to prevent forced opening or closing. When an abnormality occurs, it is necessary to repair and replace it in time. Common faults, usually pay attention to observation, and promptly eliminate the solution.
After use, the water in the pump chamber should be dried, and a small amount of neutral grease should be applied to the cone surface of the motor shaft periodically. Remove the rotor from the circulating water vacuum pump for a long time, wipe it clean and place it in a dry place.
LNEYA specializes in the production of fully enclosed heating and cooling circulators, refrigeration and heating circulators, TCU, ultra-low temperature freezer, freezer and other equipment of good quality, laughing and welcoming visitors come to negotiate!
Verwandte Empfehlungen
-
-
New energy shaft cooling chiller
1392New energy shaft cooling does not necessarily require industrial freezers, but is usually achieved using industrial chillers or cooling systems. Industrial freezers are mainly used for extremely low temperature freezing and processing, w...
Details anzeigen -
Wie wird die statische Elektrizität in der Ultra-Niedrigtemperatur-Prüfkammer kontrolliert?
1885Um die statische Qualität der Ultra-Tieftemperatur-Prüfkammer zu kontrollieren, muss die Ultra-Tieftemperatur-Prüfkammer die statische Elektrizität besser kontrollieren. Wie kontrolliert die LNEYA-Ultra-Niedrigtemperatur-Prüfkammer die statische Elektrizität...
Details anzeigen -
Low temperature heating control chip and other detection methods
1737With the research and development of chip technology, chip detection technology is also maturing. LNEYA's low-temperature heating control chip technology is applied in chip detection. In addition to this type of detection technology, there are oth...
Details anzeigen