Are hydraulic chillers the same as industrial/laboratory chillers?

The common point is that both emphasize precise control of temperature to meet the requirements of temperature stability in their respective application fields. They are usually equipped with temperature controllers, such as PID controllers, to achieve automatic regulation and control of the temperature of the cooling medium. Both transfer heat through heat exchangers (such as plate heat exchangers, shell and tube heat exchangers, etc.), transfer the heat generated by the equipment or system to the cooling medium, and then discharge it through the refrigeration cycle to achieve the cooling effect. Both rely on circulating pumps to drive the cooling medium (such as water or special coolant) to circulate in the system to ensure continuous heat transfer and uniform cooling.

The difference is that hydraulic chillers are mainly designed for hydraulic systems, used to cool hydraulic oil or other hydraulic media, to ensure that the hydraulic system can be kept within a suitable temperature range during operation, and to prevent problems such as efficiency loss, equipment damage or oil deterioration caused by overheating. Hydraulic chillers usually need to withstand higher pressures, and their design focuses more on system stability, pressure resistance, and cooling efficiency to meet the strict requirements of hydraulic systems for temperature control.

Laboratory chillers are equipment that is specifically used to cool laboratory equipment such as rotary evaporators, lasers, nuclear magnetic resonance instruments, mass spectrometers, and other precision instruments. This type of chiller usually emphasizes the accuracy and stability of temperature control, is relatively small in size, easy to operate, and has low noise, making it suitable for placement in a laboratory environment. Laboratory chillers may also have features such as intelligent control and low energy consumption to meet the special needs of scientific research and analytical experiments. According to the cooling method, they are divided into air-cooled and water-cooled types, which are widely used in plastic molding, laser processing, food processing, chemical industry, medicine, and other fields. Their design and configuration are based on the temperature range and cooling capacity requirements of specific industrial applications.

Therefore, although hydraulic chillers and industrial/laboratory chillers fundamentally achieve the purpose of heat exchange and temperature control through circulating cooling media, their respective application scenarios, design features, and performance requirements are different. Hydraulic chillers are more focused on the specific needs of hydraulic systems, while industrial/laboratory chillers are targeted at the broader fields of industrial production and scientific research, respectively.

Water Chiller Air Chiller Ölkühler

  • LTZ Wechselrichter M-Serie"      /&gt;<figcaption><span>EINSATZBEREICHE Geeignet für den Einsatz am Ziel-Temperierobjekt, das bereits über einen Kältespeicher und eine Umwälzpumpe verfügt, und das Medium durch die Umwälzpumpe in das Kältetemperiergerät der Serie LTZ M transportiert...</span></figcaption></figure></a></div><div class=LTZ Wechselrichter M-Serie

    EINSATZBEREICHE Geeignet für den Einsatz am Ziel-Temperierobjekt, das bereits über einen Kältespeicher und eine Umwälzpumpe verfügt, und das Medium durch die Umwälzpumpe in das Kältetemperiergerät der Serie LTZ M transportiert...

    Mehr
  • LN -60°C~ -10°C"      /&gt;<figcaption><span>适用范围 Produktmerkmale 产品参数 Produktparameter 行业应用 ANWENDUNG 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...</span></figcaption></figure></a></div><div class=LN -60°C~ -10°C

    适用范围 Produktmerkmale 产品参数 Produktparameter 行业应用 ANWENDUNG 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...

    Mehr
  • LT -80℃~-20℃"      /&gt;<figcaption><span>Es kann einen 24-stündigen Dauerbetrieb garantieren Umwälzende Kühlung von Ethylenglykol gemischt mit Wasser 1. Kann Ethylenglykol gemischt mit Wasser für zirkulierende Kühlung verwenden, spart Ressourcen 2.Cir...</span></figcaption></figure></a></div><div class=LT -80℃~-20℃

    Es kann einen 24-stündigen Dauerbetrieb garantieren Umwälzende Kühlung von Ethylenglykol gemischt mit Wasser 1. Kann Ethylenglykol gemischt mit Wasser für zirkulierende Kühlung verwenden, spart Ressourcen 2.Cir...

    Mehr
  • Mehr
  • LTZ Variable Frequency M series"      /&gt;<figcaption><span>It is suitable for the target temperature control object that already has a cold storage tank and a circulating pump. The medium is transported to the LTZ M series refrigeration unit through the circulating pump, which is a closed-loop refri…</span></figcaption></figure></a></div><div class=LTZ Variable Frequency M series

    It is suitable for the target temperature control object that already has a cold storage tank and a circulating pump. The medium is transported to the LTZ M series refrigeration unit through the circulating pump, which is a closed-loop refri…

    Mehr
  • LTG Screw Chiller Units"      /&gt;<figcaption><span>It is suitable for various production process cold sources in chemical, pharmaceutical, machinery and other fields, and can provide -110℃~30℃ refrigeration medium, which can be used as ice storage, low temperature air supply and ot…</span></figcaption></figure></a></div><div class=LTG Screw Chiller Units

    It is suitable for various production process cold sources in chemical, pharmaceutical, machinery and other fields, and can provide -110℃~30℃ refrigeration medium, which can be used as ice storage, low temperature air supply and ot…

    Mehr
  • ZLTZ Efficient Heat Exchanger Series"      /&gt;<figcaption><span>The ZLTZ temperature control unit is combined with a microchannelreactor to form a high heat release temperature control application.Under the same f…</span></figcaption></figure></a></div><div class=ZLTZ Efficient Heat Exchanger Series

    The ZLTZ temperature control unit is combined with a microchannelreactor to form a high heat release temperature control application.Under the same f…

    Mehr
  • LT-800 Mini-Kühler"      /&gt;<figcaption><span>LNEYA mini chiller is a small water chiller use in laboratory for rotary evaporator.</span></figcaption></figure></a></div><div class=LT-800 Mini-Kühler

    LNEYA mini chiller is a small water chiller use in laboratory for rotary evaporator.

    Mehr
  • LJ -45°C~ -10°C"      /&gt;<figcaption><span>Schnelle Kühlung und niedrige Kühltemperatur -5~-150°C Wasserkühlung LNEYA hat sich auf die Herstellung von kryogenen Einstoffkältemaschinen spezialisiert. Die Kühltemperatur reicht von -150°C bis -5°C, was die Kühlleistung...</span></figcaption></figure></a></div><div class=LJ -45°C~ -10°C

    Schnelle Kühlung und niedrige Kühltemperatur -5~-150°C Wasserkühlung LNEYA hat sich auf die Herstellung von kryogenen Einstoffkältemaschinen spezialisiert. Die Kühltemperatur reicht von -150°C bis -5°C, was die Kühlleistung...

    Mehr
  • LD -80°C~ -30°C"      /&gt;<figcaption><span>1. die Temperatur reicht von -5℃ ~ -150℃, können verschiedene Temperatur2 erfüllen. Berühmte Marke halbgeschlossenen Kolbenverdichter, halbgeschlossenen bipolaren Kolbenverdichter, halbhermetischen Schraubenverdichter, Hauptmarke sind BOCK. Bitzer,...</span></figcaption></figure></a></div><div class=LD -80°C~ -30°C

    1. die Temperatur reicht von -5℃ ~ -150℃, können verschiedene Temperatur2 erfüllen. Berühmte Marke halbgeschlossenen Kolbenverdichter, halbgeschlossenen bipolaren Kolbenverdichter, halbhermetischen Schraubenverdichter, Hauptmarke sind BOCK. Bitzer,...

    Mehr
  • LT -45℃~30℃"      /&gt;<figcaption><span>KÜHLKREISLÄUFER FÜR NIEDRIGE TEMPERATUREN Für schnelle Flüssigkeitskühlung 1. Kann Ethylenglykol gemischt mit Wasser für zirkulierende Kühlung verwenden, spart Ressourcen 2.Circulating Pipeline Design, verlängern...</span></figcaption></figure></a></div><div class=LT -45℃~30℃

    KÜHLKREISLÄUFER FÜR NIEDRIGE TEMPERATUREN Für schnelle Flüssigkeitskühlung 1. Kann Ethylenglykol gemischt mit Wasser für zirkulierende Kühlung verwenden, spart Ressourcen 2.Circulating Pipeline Design, verlängern...

    Mehr
  • LT -60℃~-20℃"      /&gt;<figcaption><span>Circulating refrigeration of ethylene glycol mixed with water mixture After the medium enters the extraction tank, it must be closed,the sandwich is heated, and the refrigerant is turned on to reducethe heat source of the…</span></figcaption></figure></a></div><div class=LT -60℃~-20℃

    Circulating refrigeration of ethylene glycol mixed with water mixture After the medium enters the extraction tank, it must be closed,the sandwich is heated, and the refrigerant is turned on to reducethe heat source of the…

    Mehr

Laden...

已经是到最后一篇内容了!

Die vorl: Die nächste:

Verwandte Empfehlungen