Precautions for installing reactor refrigeration and heating circulator
The reactor refrigeration and heating cycle equipment can achieve high temperature of 200℃ and low temperature constant temperature test of -120℃, providing users with a field source with controlled thermal cooling and constant temperature. It can also be used as a heat source or cold source for direct heating, cooling, auxiliary heating, and auxiliary refrigeration. Source, temperature control within the full range, used in diffusion process control of semiconductor diffusion furnaces, constant temperature control or external circulation applications in reactors, fully automatic synthesis instruments, extraction and condensation devices.
Working principle of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment uses coolant as the heat transfer medium to transport the heat generated by other instruments or equipment that need to be cooled, and sends the heat to the outside of the equipment through the refrigeration system to ensure that the equipment works within the normal temperature range. The device and the instrument rely on the pressure of the pump in the device to form a closed medium circulation, and the temperature sensor is used to detect the temperature of the medium to realize the control of the cooler.
Installation environment of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment has a semi-closed cycle. At high temperatures, no oil mist evaporates, and the thermal oil will not be oxidized and browned. At low temperatures, it will not absorb water vapor in the air, extending the life of the thermal oil. Reactor refrigeration and heating cycle equipment should be installed in a laboratory with a good environment; it should be installed on a well-ventilated, dust-free, stable floor or experimental table to avoid droplets, excess vapor, and possible inflow, stagnation, and leakage of flammable gases. Avoid places that can generate high-frequency equipment (high-frequency welding machines, etc.).
When the reactor refrigeration and heating cycle equipment avoids frequent use of acidic solutions and frequent use of special sprayers (containing sulfides, etc.), from the perspective of convenience and safety during maintenance and installation, try to ensure that there is a gap between the indoor unit and obstacles. have enough space.
Follow the instructions when installing:
The use of 300°C refrigeration and heating cycle equipment is inseparable from its standardized operation. When selling, there will be corresponding instructions for use when the equipment leaves the factory. Users can understand it in advance when using it.
The reactor refrigeration and heating cycle equipment is simple to install and operate, and does not require professional operation. The operator can be operated with simple training or by following the instructions; the heating method is circulating heating, so there is no loss of the medium; no need Annual review.
Zusammenfassend
The reactor refrigeration and heating cycle equipment is heated evenly, and the temperature adjustment adopts PID self-tuning intelligent control. The temperature control accuracy is ±1°C, which can meet the strict requirements of high process standards. Closed cycle heating, small heat loss, wide range of use.
SUNDI Z Frequenzumwandlungsserie
WHATSAPP WECHAT Ultrahochtemperatur-Kühltechnologie kann direkt von einer hohen Temperatur von 300℃[kühlen, weil nur das Wärmeträgermedium in der...
SUNDI -10℃~150℃
Vollständig geschlossenes System, einzelne Medium vervollständigt Kühlung und Heizung -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Ultra Hochtemperatur-Kühltechnik kann direkt von einem hohen...
SUNDI -80℃~250℃
● Arbeitstemperaturen von -120°C bis +350°C ● Bisher unerreichte Leistung ●Intelligente Temperaturregelung ● Maximale Prozessstabilität und Reproduzierbarkeit ● Adop-Plattenwärmetauscher, Pipelineheizung, die schnellste...
SUNDI-320/320W
Völlig geschlossenes System, einzelnes Medium vervollständigt Kühlung und Heizung -120~350℃ ±0.5℃ Ultra-Hochtemperatur-Kühltechnologie kann direkt von 300℃ hoher Temperatur abkühlen. Bec...
SUNDI -25℃~200℃
Vollständig geschlossenes System, ein einziges Medium ergänzt Kühlung und Heizung -120~350℃ ±0,5℃ ● Arbeitstemperaturen von -120°C bis +350°C ● Bisher unerreichte Leistung ●Intelligente Temperaturregelung...
SUNDI -25℃~300℃
● Arbeitstemperaturen von -120°C bis +350°C ● Bisher unerreichte Leistung ●Intelligente Temperaturregelung ● Maximale Prozessstabilität und Reproduzierbarkeit ● Adop-Plattenwärmetauscher, Pipelineheizung, die schnellste...
SUNDI -45℃~250℃
● Arbeitstemperaturen von -120°C bis +350°C ● Bisher unerreichte Leistung ●Intelligente Temperaturregelung ● Maximale Prozessstabilität und Reproduzierbarkeit ● Adop-Plattenwärmetauscher, Pipelineheizung, die schnellste...
SUNDI -60℃~250℃
Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with ox…
Laden...
已经是到最后一篇内容了!
VIDEO
Verwandte Empfehlungen
-
Application of refrigeration and heating temperature control system in chemical synthesis
864chemical synthesis cooling heating system temperature control unit
Details anzeigen -
SUNDI -90℃~250℃
2404● Arbeitstemperaturen von -120°C bis +350°C ● Bisher unerreichte Leistung ●Intelligente Temperaturregelung ● Maximale Prozessstabilität und Reproduzierbarkeit ● Adop-Plattenwärmetauscher, Pipelineheizung, die schnellste...
Details anzeigen -
KRY -40℃~+100℃ (1to2)
2454Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and pressure independently while c...