Analyse von häufigen Fehlern im Batterietestsystem für New Energy Vehicle Power
If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the body all connections (positive and negative lead, sampling line interface) .
Close the maintenance switch assembly, multimeter test battery pack parameters: closed maintenance switch, use a multimeter to measure the total voltage of the power battery V, use a multimeter to measure the positive and body voltage V1, use a multimeter to measure the negative and body voltage V2, multimeter pen replacement Parallel fixed value resistance meter pen, and set the gear position to the resistance file, measure the fixed value resistance value R, multimeter table position back to the DC voltage file, measure the parallel resistance, the positive pole and the body voltage V1, measure the parallel resistance, the negative pole and the body After the voltage V2 is measured, disconnect the maintenance switch.
If a new energy vehicle battery encounters a temperature-type fault, it means that the vehicle does not have an OK file. The instrument panel indicates that the power battery temperature is too high. After a temperature alarm occurs, the manager, the wiring harness, and the like need to be excluded (replacement manager, The manager and the battery pack are connected to the sampling harness); if the fault persists after the replacement, it is judged that the power battery is faulty.
Wuxi Guanya New Energy Battery Cooling Test System Platform reminds that if the power battery is seriously unbalanced, check the vehicle for full charge and charge, and switch BMS test 80%, 50%, 0% single-cell battery voltage data flow, observe and compare If the low battery voltage is the same, the fault still replaces the power battery.
If there are other faults in the battery pack in the automotive power battery test system, it is recommended to contact the battery manufacturer for processing.
Verwandte Empfehlungen
-
Common Failures of Salt Spray Environmental Chambers
1633When you encounter some common failures of salt spray environmental chambers, how to solve them? Wuxi Guanya Refrigeration Technology Co., Ltd. has brought the relevant fault tips as follows.Salt spray environmental chamber cannot sprayFailure cau...
Details anzeigen -
Anwendungsbereich der LNEYA-Wasserumwälzpumpe
1834Die Warmwasserzirkulation ist ein sehr gutes Gerät zur Warmwasserbereitung und wird heute vielerorts eingesetzt. Mit einem Warmwasserzirkulator kann man das Problem des Warmwasserverbrauchs im Haushalt lösen. Heute werden wir einige Anwendungen der Warmwasserzirkulation vorstellen...
Details anzeigen -
Ultra-high temperature material cold and hot impact box refrigeration oil
1866The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature materia...
Details anzeigen -
API China [A1A20-2] welcomes new and old customers!
1858API China, as a long-standing and large-scale exhibition in China's industrial field, has promoted and witnessed the development and growth of the pharmaceutical industry, and has also been accompanied by generations of Chinese pharmaceutical peop...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant