Heat sink temperature application note
As we all know, the semiconductor industry has certain characteristics, small size, high reliability, wide working range, and has a wide range of applications in the civilian, industrial and other fields of semiconductors, but with the increasing output power of semiconductors, its waste heat effect More and more prominent, the temperature of semiconductor devices is also getting higher and higher, resulting in lower and lower conversion efficiency, and the position of the lasing wave is shifted. The heat sink temperature control of Wuxi Guanya can control the temperature of the microchannel heat sink of the semiconductor device at different temperature ranges to control the temperature. The heat sink temperature control is suitable for the heat and heat release process control during the reaction process, and the temperature of the semiconductor device is accurately and linearly controlled. The program control mode can be selected, and the heat transfer medium and the temperature difference can also be set. The heat sink temperature control system adopts a fully closed cycle, which does not generate oil mist at high temperature, and does not absorb moisture at low temperature. There is an expansion tank in the system, and the heat transfer medium expands and contracts during cooling and heating.

The heat sink temperature control adopts self-developed high-temperature resistant and low-temperature magnetic drive non-leakage pump to reduce the risk of leakage. At the same time, it has low noise, large flow, long lift, large flow rate, low heat generation and other advantages. At the same time, it adopts variable frequency motor, which can be controlled by frequency conversion according to user requirements, and is more suitable for overshooting reaction of short-term intense heat release and heat absorption. The temperature range of the heat sink temperature control uses Emerson’s electronic expansion valve to precisely control the number of steps of the stepper motor, thus precisely controlling the electronic expansion valve opening (percentage of opening), in order to accurately control the evaporation of the compressor refrigerant The purpose is to optimize the refrigeration state of the compressor, reduce the process fluctuation caused by the change of the refrigeration power of the compressor, and improve the control precision and control stability.
Heat sink temperature control has certain requirements in performance, so it is better to require heat sink temperature control manufacturers to have certain guarantees for performance and after-sales service.
Verwandte Empfehlungen
-
How to solve the problem that the cooling pump centrifugal pump power consumption becomes larger?
1032There are many opportunities for the centrifugal pump in the chiller, but the failure of the centrifugal pump will affect the use of the chiller. Therefore, do not worry if the centrifugal pump power becomes larger, find out the cause in time, and...
Details anzeigen -
Wann sollte man sich für ein TCU-Temperaturkontrollsystem entscheiden?
976Zunächst einmal muss man wissen, dass der Reaktionskessel in der Regel neben der chemischen Reaktion des Materials selbst auch die notwendige Temperaturregelung durchführen muss. Durch die Temperaturveränderung des zirkulierenden Mediums im Mantel ...
Details anzeigen -
Fehlerbehebung bei Lüfterausfällen im Kühlsystem des Motorantriebsstrangs
955The fan is generally installed at the upper end of the cooling system of the engine powertrain, and some customers choose to install it on the side according to regulations. For screw chillers that use fans to dissipate heat, they are called air-c...
Details anzeigen -
What type of temperature control system is required for smear preparation in the pharmaceutical industry?
856In the pharmaceutical industry, negative pressure drying and smear preparation have specific requirements for temperature control, and usually require precise and adjustable temperature control devices to ensure product quality and process sta...
Details anzeigen