Theorie des Eisflusses, Eiswasserqualität, Durchfluss und Druck der Eiswassermaschine
The softening of water is also an important problem in the process of using chillers.The pH value of water also needs to be continuously observed. The optimum pH value should be equal to 7. The pH value greater than 7 will cause terrible corrosion. If no measures are taken, fouling will be built in the evaporator and die, which will play an insulating role, and the energy conversion effect will be reduced by 30% in severe cases. Obviously this requires consideration of the softening of hard water.
The most effective method is to configure an electronic hard water softener in the system, which is designed and manufactured separately from the exchange principle. Softeners of different specifications can be configured according to different flow rates, which can be directly connected to the circulating water pipeline.
Generally, the cost of water treatment softener is not too high, and a certain proportion of scale removal agent can be added to the periodic circulation system. Generally, when the injection moulds are cooled and the pressure of ice water is 0.1-0.2 mpa, the requirements can be met. When the pressure requirement is higher than 0.2 mpa, it is necessary to plan separately in order to use the corresponding pressure from the pump to meet the need of water supply.
We are a top chiller manufacturer. Welcome to buy our products.
Verwandte Empfehlungen
-
Description of operation characteristics of fully enclosed refrigeration and heating machine
1383In the petroleum, chemical, and pharmaceutical industries, fully enclosed refrigeration and heating integrated machines are needed by many enterprises. However, when users choose to make choices, they must understand their operating characteristic...
Details anzeigen -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
1069The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
Details anzeigen -
Refrigeration Explanation for Screw Compressor of Low Temperature Chiller Circulator
1177Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the ...
Details anzeigen -
Constant temperature circulation device can help chip to complete reliability test
944As the country vigorously develops domestic chips, chip manufacturing is entering the fast lane. After the chip is manufactured, there is a very critical link, which is the reliability test, and the constant temperature circulation device can quic...
Details anzeigen