Was sind die wichtigsten Vorteile von Ölkühlern für die biopharmazeutische Industrie?
In the refrigeration system of the oil cooler in the biopharmaceutical industry, the compressor, the evaporator and the condenser are the indispensable parts of the refrigeration system. The condenser is the equipment that emits heat, which combines the heat absorbed in the evaporator with the compressor The heat converted by the work is transferred to the cooling medium to take away together, which is responsible for the important components of the refrigeration system. If the function decreases, it will directly affect the refrigeration capacity.

There are two main types of condensers used in biopharmaceutical industrial oil coolers: air-cooled condensers and water-cooled condensers. Depending on the type of condenser, the method of cleaning the scale is also different.
1. The air-cooled condenser uses air as the cooling medium. Since there is often dust in the air, some of the dust will stick to the outer surface of the condenser fins. Over time, the cooling effect of the condenser will become worse. Especially in places where the environment is relatively harsh, it should be cleaned regularly. The cleaning method is: pure dust can be cleaned with compressor air, etc. If there is a lot of dirt, a non-corrosive cleaning agent should be used to clean the heat pipe and fins to achieve the purpose of improving the heat dissipation effect.
2. For water-cooled condensers, the main problem is to remove scale. The cleaning cycle depends on the water quality. If the water quality is poor, it can be cleaned at least once a year; if the water quality is good, it can be cleaned once every 2 to 3 years.
3. It can be cleaned with special cleaning fluid for heat exchangers. The specific operation method is: remove the condenser, release the accumulated water, and then clean the liquid in the tube until the water outlet has the position where the solution flows out.
The performance of the condenser of the oil cooler in the biopharmaceutical industry will gradually decline if it is used for a long time. As a result, the condensing pressure of the system will be higher than the condensing pressure during normal operation. Regularly protect and maintain the condenser. Here is a brief introduction to the two commonly used condenser protection and maintenance.
Verwandte Empfehlungen
-
Detailed Electric Vehicle Motor Test And Test System
1033New energy vehicles need to have power system, drive system, control system integration test capability, and electronic electronic control test system function test capability. For component manufacturers, this test development capability is also ...
Details anzeigen -
Anwendungstechnik zur Erkennung von Chip-Temperaturkontrollgeräten
1114Das Chip-Temperaturkontrollgerät wird hauptsächlich im Bereich der Chip-Prüfung eingesetzt. Für verschiedene Arten von Chip-Typen, die Erkennung Technologie muss auch Aufmerksamkeit, so ist es notwendig, die Aufmerksamkeit auf die praktische Anwendung der verschiedenen...
Details anzeigen -
Wie wählt man das Modell des Temperaturreglers der Lithografiemaschine aus?
903Wie wählt man einen geeigneten Industriekühler aus, und welche Aspekte sollten bei der Konstruktion des Geräts beachtet werden?1. Wählen Sie ein luftgekühltes oder wassergekühltes Temperiergerät für eine Lithographie-MaschineDie Kondensationsmethoden von Industriekälte...
Details anzeigen -
Introduction to cold plate liquid cooling system products and equipment
1119Introduction to cold plate liquid cooling chiller
Details anzeigen