Verfahren zur Steuerung des Abschaltens eines wassergekühlten Kühlers eines einzelnen Reaktionskessels
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
Verwandte Empfehlungen
-
Function of Evaporator in Air Cooled Chiller
1032The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
Details anzeigen -
What should you pay attention to when installing a DC charging pile cooling system?
838Before installing a DC charging pile cooling system, you need to understand the characteristics of the equipment. This includes things like the device's size, weight, operating temperature range, and power requirements. Ensure that the equi...
Details anzeigen -
Wartung des Kühlaggregats für die Wasserkühlung der UV-Ätzmaschine
1097Ultraviolettes Ätzen Maschine Wasserkühlung Einheit Kühler ist eine Art von Kälteanlagen weit verbreitet in der industriellen Produktion. Es kann eine effektive Kühlung Umwelt für verschiedene industrielle Produktionen bieten, und es kann große Konvektion...
Details anzeigen -
Beschreibung der Typenauswahl und Klassifizierung von 40-GW-Kaltwassersätzen
1123Wenn verschiedene Unternehmen und verschiedene Branchen unterschiedliche Anforderungen an Wuxi Guanya 40GW kryogenen Kältemaschinen haben, ist seine Modellauswahl auch unterschiedlich. So ist es besser, ein klares Verständnis der Bedürfnisse der Auswahl der 40GW kryog...
Details anzeigen