The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Verwandte Empfehlungen
-
Vacuum chamber cooling chiller
931Vacuum chamber cooling chiller is a device specially designed to cool the environment in a vacuum chamber to ensure that the temperature in the vacuum chamber is kept within the required working range to meet the needs of specific applicatio...
Details anzeigen -
200L Kristallisationsauflösungs-Kessel Kühl- und Heizsystem
824Für die Bedürfnisse der 200L Kristallisation Auflösung Kessel Kühlung und Heizung System-Anwendungen, diese Art von Ausrüstung ist in der Regel in der Kristallisation, Auflösung und andere Prozesse in den Bereichen der chemischen Industrie, Pharmazie...
Details anzeigen -
Vocs condensation adsorption technology energy control instructions
1244The vocs condensation adsorption technology has been developed under the current trend of environmental protection. The LNEYA vocs condensation adsorption technology uses condensation adsorption technology. In order to save operating costs, it is ...
Details anzeigen -
What tests are used by cooling water chillers for new energy enterprises?
912In the process of product development, production and quality control, new energy enterprises will use cooling water chillers to perform a variety of tests. Cooling water chillers play an important role in these tests to ensure the perform...
Details anzeigen