Wartung einer Vakuumpumpe für eine vollständig geschlossene Heizungs- und Kühlungsumwälzanlage
Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump?
For the fully enclosed heating and cooling circulator circuit, the electronic circuit and the mechanical rotating part are routinely inspected and repaired. Pay attention to whether the various indicators are damaged or deteriorated, and regular maintenance is required.

Do the vacuum pump working status and the registration of each working time, record the cause of the instrument failure and the troubleshooting method in time to ensure that the vacuum pump works in a better state.
Keep the vacuum pump symmetrically balanced. If the sample tube placed in the pump chamber is unbalanced, it will cause the circulating water vacuum pump to shift. After the shutdown is reset, check if the vacuum pump is normal.
Before use, please pay attention to check the rotor for corrosion points and fine cracks. The rotor that has been corroded or cracked is forbidden to use. If the rotor exceeds the shelf life, it should be checked frequently to ensure personal safety.
The fully enclosed heating and cooling circulator vacuum pump cover door bolts should be checked frequently and kept flexible to prevent forced opening or closing. When an abnormality occurs, it is necessary to repair and replace it in time. Common faults, usually pay attention to observation, and promptly eliminate the solution.
After use, the water in the pump chamber should be dried, and a small amount of neutral grease should be applied to the cone surface of the motor shaft periodically. Remove the rotor from the circulating water vacuum pump for a long time, wipe it clean and place it in a dry place.
LNEYA specializes in the production of fully enclosed heating and cooling circulators, refrigeration and heating circulators, TCU, ultra-low temperature freezer, freezer and other equipment of good quality, laughing and welcoming visitors come to negotiate!
Verwandte Empfehlungen
-
Instructions On Refrigeration Of Low Temperature Chiller Circulating Machine Screw Compressor
1282Due to different compressors, the performance of low temperature chiller circulation machine is also different. Screw compressor is different from the piston compressor, whose structure is more sophisticated. Therefore, if the user needs to choose...
Details anzeigen -
How to replace the four-way valve of the chilled water machine?
1070The four-way valve of the chilled water machine needs to be replaced in time after a long period of use, so how to replace it? You can look at the suggestions. When replacing the chilled water machine, you need to remove the connecting pipe conne...
Details anzeigen -
What aspects should be paid attention to when using laboratory cryogenic refrigeration circulators?
993The compact circulating cooler is an economic model for routine laboratory applications. The instrument is cooled in the temperature range of -10 or 0°C to +40°C, and the temperature control accuracy can reach ±0.5°C. It is a good way to replace e...
Details anzeigen -
What are the causes of the blockage of the cooler?
976The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
Details anzeigen