Explosion-proof hot and cold machine winter maintenance instructions
When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it in a dry place to prevent freezing and expansion. Damage to machine parts (such as coolers, pumps, connecting copper pipes). The method of removing residual water is as follows:
1. The water sequence series needs to disconnect the cooling water and hot water inlet and outlet pipes and open the corresponding ball valve. Take the air gun to the hot water (outlet) inlet and let the residual medium inside the system discharge from the cooling water inlet (cooling) The water outlet is discharged from the inlet due to the electromagnetic valve. It is determined that there is no water in the pipeline and it can be stopped.
2. The standard explosion-proof type hot and cold integrated machine needs to disconnect the connecting pipe of the cooling water inlet and outlet, open the ball valve and let the machine be in a cooling state. When the cooling electromagnetic valve is opened, take the air gun and blow it into the cooling water inlet to make it from the water outlet. Discharge, determine that there is no water in the pipeline and then stop.
Kindly note, please be sure to disconnect the cooling water connection pipe when the equipment is not in use, and clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.
In the winter, when you do not need the explosion-proof type hot and cold machine, you need to pay attention to turn off the explosion-proof hot and cold machine and clean it as well, so as to avoid the residue affecting the performance of the explosion-proof hot and cold machine.
Verwandte Empfehlungen
-
Tägliche Wartung der Tiefkühltruhe
939Tiefkühlgeräte, die auch als Industriekühlschränke bezeichnet werden, werden hauptsächlich für die industrielle Kältebehandlung, die Erhöhung der Verschleißfestigkeit und die Reibung von Metallen verwendet. Guanya Refrigeration Technology Co. in Wuxi ist eine führende Rolle...
Details anzeigen -
Which industries are applicable to semiconductor device testing?
1114Semiconductor device testing is used in many semiconductor industries. So, how much do you know about semiconductors and conductors for semiconductor device testing? The properties of this substance are still recommended to the user. In general, s...
Details anzeigen -
Detailed Electric Vehicle Motor Test And Test System
1028New energy vehicles need to have power system, drive system, control system integration test capability, and electronic electronic control test system function test capability. For component manufacturers, this test development capability is also ...
Details anzeigen -
The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
1321Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system...
Details anzeigen