Suche im gesamten Bahnhof

Kühlung-Heizung-Kombination

SUNDI -90℃~+250℃

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 1)
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 2)
Kühlleistung 0,5kW~80kW
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 3)
Heizleistung 5,5kW~80kW
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 4)
Medium temp accuracy ±0.5℃
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 5)
Energie wird verbraucht

The SUNDI-90℃~250℃ chiller heater combo has both cooling and heating capabilities, and has an extremely wide temperature range. It can easily handle the working range of -90℃ to 250℃ and is suitable for various extreme working environments.

LNEYA has mastered the core technology of direct compression refrigeration from 300℃, so the SUNDI-90℃~250℃ chiller heater unit can quickly heat up or cool down in a short time, and quickly switch between cooling and heating to ensure the connection of your process flow.

SUNDI- 955W 975W 9A10W 9A15W 9A25W 9A38W 9A60W 9A80W
Temperaturbereich   -90℃~+250℃
Mittlere Temperaturgenauigkeit ±0.5℃
Genauigkeit der Materialtemperatur ±1℃
Heizleistung 5.5 7.5 10 15 25 38 60 80
Kühlleistung 250℃ 5.5 7.5 10 15 25 38 60 80
0℃ 5.5 7.5 10 15 25 38 60 80
-60℃ 2.8 3.2 4.2 6 10 16 24 32
-80℃ 0.8 1.2 1.6 2.1 3.5 6 11 15
-85℃ 0.5 0.7 0.85 1.3 1.9 3.5 6 8
Flow、pressure max
L/min bar
35 50 60 110 150 250 400 400
1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Kühlwasser
@20℃
3400L/H
1,5bar~4bar
ZG1
4500L/H
1,5bar~4bar
ZG1
5200L/H
1,5bar~4bar
ZG1 1/4
8m³/H
1,5bar~4bar
DN40
12m³/H
1,5bar~4bar
DN50
20m³/H
1,5bar~4bar
DN65
30m³/H
1,5bar~4bar
DN80
40m³/H
1,5bar~4bar
DN100
Leistung 380V 50HZ 16kW 27kW 30kW 42kW 59kW 83kW 130kW 188kW

Tragbarer Luft- und Wasser-Chiller

Drei-Punkt-Temperaturregelung

20 Programme können kompiliert werden

Der Schlüssel zur Gewährleistung hoher Präzision und hoher Effizienz

Vorteile von Kühlung-Heizung-Kombination

Energieeinsparung Die SUNDI-90℃~250℃ Chiller-Heizer-Einheit kann den geeigneten Wasserfluss automatisch entsprechend dem tatsächlichen Kühlbedarf einführen, um den Kühlwasserverbrauch zu reduzieren. Aufrüstbare Frequenzumrichter-Modelle helfen Ihnen, Betriebskosten effektiv zu sparen. Umweltschutz LNEYA geht seit jeher aktiv seinen Umweltschutzpflichten nach. Der SUNDI-90℃~250℃ Chiller-Heizer verwendet umweltfreundliche Kältemittel, die die Ozonschicht nicht zerstören. Geringere CO₂-Emissionen helfen Ihrem Unternehmen, seinen CO₂-Fußabdruck zu reduzieren. Der Chiller arbeitet mit sehr niedriger Betriebslautstärke und bietet Ihnen eine angenehmere Arbeitsumgebung.

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 6)
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 7)
Der Schlüssel zur Gewährleistung hoher Präzision und hoher Effizienz

Kühlung-Heizung-Kombination Anwendungen

Pharmazeutische chemische Industrie Verschiedene chemische Reaktionen müssen bei unterschiedlichen Temperaturen durchgeführt werden. Um die Stabilität und Sicherheit des Reaktionsprozesses zu gewährleisten, ist es notwendig, auf die Chiller-Heizer-Kombination zur genauen Temperaturkontrolle zurückzugreifen. Biologische Produktion Als Beispiel sei die Zellkultur in der Biotechnologie genannt. Verschiedene Wachstumsstadien erfordern unterschiedliche Temperaturen. Ob hohe oder niedrige Temperaturen, der SUNDI-90℃~250℃ Chiller-Heizer kann schnell über Kühl- und Heizfunktionen angepasst werden. Halbleiterindustrie Um die Ausbeute zu sichern und die Lebensdauer der Halbleiterausrüstung zu verlängern, verwenden Halbleiterunternehmen häufig Chiller zur Steuerung der Temperaturumgebung. Ob Waferherstellung, Ionenimplantation, Ätzen, Reinigung, Verpackung oder Testen – die Unterstützung durch Chiller ist unverzichtbar.

ANDERES MODELL für DYNAMISCHE TEMPERATURSTEUERUNGSSYSTEME

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 8)

SUNDI -10℃~+150℃
Chiller-Heizeinheit

Kühlleistung 2,1kW~15kW
Heizleistung 3,5kW~15kW

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 9)

SUNDI -25℃~+200℃
Heiz-/Kühlzirkulator

Kühlleistung 1,8kW~200kW
Heizleistung 3,5kW~200kW

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 10)

SUNDI -45℃~+250℃
Heizungskühler

Kühlleistung 0,25kW~200kW
Heizleistung 2,5kW~200kW

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 11)

SUNDI -60℃~+250℃
Warmwasserbereiter und Kühler

Kühlleistung 0,25kW~60kW
Heizleistung 2,5kW~60kW

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 12)

SUNDI -80℃~+250℃
Wasserkühler-Heizung

Kühlleistung 0,3kW~80kW
Heizleistung 3kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 13)

SUNDI -90℃~+250℃
Kühler-Heizung-Kombination

Kühlleistung 0,5kW~80kW
Heizleistung 5,5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 14)

SUNDI -100℃~+100℃
Rückkühler mit Wärmetauscher

Kühlleistung 0,7kW~80kW
Heizleistung 5,5kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 15)

SUNDI-320
tragbare Kühlbox

Kühlleistung 0,4kW~1,5kW
Heizleistung 2kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Fügen Sie unseren Account-Manager über den untenstehenden QR-Code hinzu

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 16)
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 17)
<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 18)

You can trust Kühlung-Heizung-Kombination factory

Wir sind ein sehr leistungsstarker Kühlerlieferant mit eigener Fabrik und mehr als 20 Jahren Erfahrung im Bereich der Temperaturregelung

LNEYA verpflichtet sich zu technologischen Innovationen. 20% der Mitarbeiter des Unternehmens sind Techniker, und alle Mitarbeiter haben eine professionelle Ausbildung erhalten. Derzeit haben wir fast 90 Patente erhalten und arbeiten weiterhin an der Optimierung des Produktdesigns.

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 23)

Globaler Service

Mehr als 30.000 Kunden bedient.
Export in über 20 Länder.

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 24)

Zertifizierungspatente

Hat CE-Zertifizierung, SGS-Zertifizierung, ISO-Zertifizierung erhalten

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 25)

Kundendienst

Umfassende technische Schulungen anbieten.
Mit 24/7-Lösungen.

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 26)

Professionelles Team

Gegründet 2010, mit 15 Jahren Branchenerfahrung.
20 % der Mitarbeiter sind Techniker.

<trp-post-container data-trp-post-id='13111'>Chiller Heater Combo</trp-post-container>(images 27)

Qualitätskontrolle

Sichtprüfung.
Leistungstest.
Elektrische Sicherheitsprüfung.

Die SUNDI-90℃~250℃ Chiller-Heizer sind für Branchen wie Medizin, chemische Industrie, Biotechnologie, Halbleiterfertigung, Laborforschung, Luft- und Raumfahrt usw. geeignet und eignen sich für nahezu alle Szenarien, die eine präzise Temperaturregelung erfordern.

Ja, wir sind ein Chiller-Hersteller und können Größe, Temperaturbereich, Kühl- und Heizleistung, Spannung, Schnittstellentyp usw. des Chillers nach Ihren Bedürfnissen anpassen. Ob tragbarer Chiller, kleiner oder großer Chiller – wir können Lösungen basierend auf Ihrer spezifischen Anwendung anbieten.

*
*
Submitting….
Erfolgreich gesendet!
Übermittlung fehlgeschlagen! Bitte versuchen Sie es später erneut
E-Mail-Fehler!
Telefonfehler!