heat recovery chiller
HR -20℃~200℃
The heat recovery chiller can recover the waste heat generated by the compressor and use it for heating. It has both cooling and heating functions, giving you a convenient temperature control solution.
HR heat recovery chiller overview
The HR heat recovery chiller offers precise temperature control. It is designed for heating and cooling in process applications. The system includes heating, cooling, circulation, and control functions. The heat transfer fluid moves between the reactor jacket and the chiller. This allows stable and efficient heat exchange. Users can set and monitor the temperature in real time.
±0.5°C
Genauigkeit der Temperaturregelung
HR heat recovery chiller parameters
Modell |
HR-35N |
HR-50N |
HR-70N |
HR-100N |
HR-150N |
Temp rang |
-25℃~200℃ |
Temp accuracy |
±0.5℃ |
Heating power KW |
3,5 kW |
5,5 kW |
7kW |
10kW |
15kW |
Kühlung Capacity kW at |
200℃ |
3,5 kW |
5,5 kW |
7kW |
10kW |
15kW |
100℃ |
3,5 kW |
5,5 kW |
7kW |
10kW |
15kW |
20℃ |
3,5 kW |
5,5 kW |
7kW |
10kW |
15kW |
-5℃ |
3kW |
4,5 kW |
6,6 kW |
8kW |
12kW |
-15℃ |
1,8 kW |
2,8 kW |
3,8 kW |
4,6 kW |
7kW |
Criculation pump flow |
Max35L/min |
Max35L/min |
Max50L/min |
Max60L/min |
Max110L/min |
Pressure MAX |
1.2BAR |
1.2BAR |
1.2BAR |
1.5BAR |
1.5BAR |
Kältemittel |
R-404A/R507C |
Abmessung cm |
45*70*160 |
45*70*160 |
55*70*175 |
65*85*185 |
70*85*185 |
Power max AC 380V 50HZ |
6,5 kW |
8kW |
13kW |
18kW |
26kW |
heat recovery chiller features
The HRT industrial heater chiller has a self diagnostic function. If a fault occurs, the cause of the fault will be displayed at the top of the touch screen, making it convenient for you to troubleshoot in a timely manner.
HRT can control the temperature of the thermal medium within ± 0.5 ℃, but as an economical chiller heater, it does not support controlling the temperature of the reactants. If you need to control the temperature of the reactants, you can choose the Baureihe SUNDI.
heat recovery chiller APPLICATIONS
HR heat recovery chiller is suitable for almost all scenarios that require stable, accurate and efficient temperature control.
heat recovery chiller related
HR -25℃~200℃
boiler chiller systems
why us?
Globaler Dienst
30.000 +Kunden.
20+ Länder.
Zertifizierung von Patenten
CE, SGS, ISO-Zertifizierung.
Service nach dem Verkauf
24/7 solutions.1-year warranty
Professionelles Team
Mehr als 15 Jahre Erfahrung.
Qualitätskontrolle
Qualitätsprüfung.
faq
Finden Sie keinen passenden Kühler? Oder wissen Sie nicht, wie Sie ihn auswählen sollen? Kontaktieren Sie uns jetzt für Details und Preise.
Kontakt zu LNEYA
Schicken Sie uns Ihre Anfrage und wir werden Sie innerhalb von 24 Stunden kontaktieren.