Operating Principle
LNEYA nimmt den weltberühmten Markenkompressor an, der die Lebensdauer des Industriekühlers von -10 ° C bis 200 ° C verlängern kann, den Kühleffekt verbessert, den Energieverbrauch und die Geräusche des Industriekühlers von -10 ° C bis 200 ° C verringert.
Model | CDLJ-2W | CDLJ-3W | CDLJ-4W | CDLJ-6W | CDLJ-10W | CDLJ-15W | CDLJ-20W | CDLJ-30W | CDLJ-45W | CDLJ-60W | CDLJ-120W |
Arbeits temp. bereich | -115°C~ -50°C | ||||||||||
Kälte leistung | 3kw | 4.5kw | 6kw | 9kw | 15kw | 22.5kw | 30kw | 45kw | 67.5kw | 90kw | 180kw |
At -90°C Kcal/h | 2580 | 3870 | 5160 | 7740 | 12900 | 19350 | 25800 | 38700 | 58050 | 77400 | 154800 |
Kälte leistung | 2kw | 3kw | 4kw | 6kw | 10kw | 15kw | 20kw | 30kw | 45kw | 60kw | 120kw |
At -110°C Kcal/h | 1720 | 2580 | 3440 | 5160 | 8600 | 25800 | 17200 | 25800 | 38700 | 51600 | 103200 |
Pumpenleistung Druck Saug |
6.6m³/h | 6.6m³/h | 6.6m³/h | 15m³/h | 15m³/h | 15m³/h | 25m³/h | 25m³/h | 35m³/h | 35m³/h | 50m³/h |
2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | |
Interface Größe |
DN-25 PN-10 |
DN-25 PN-10 |
DN-25 PN-10 |
DN-32 PN-10 |
DN-32 PN-10 |
DN-32 PN-10 |
DN-40 PN-10 |
DN-40 PN-10 |
DN-50 PN-10 |
DN-50 PN-10 |
DN-50 PN-10 |
Kühlwasser 30 DEG |
10m³/h | 14m³/h | 20m³/h | 25m³/h | 35m³/h | 45m³/h | 65m³/h | 90m³/h | 120m³/h | 180m³/h | 360m³/h |
EIS - Panzer(Auswahl) (optional) |
100L | 150L | 150L | 250L | 300L | 500L | 500L | 750L | 1000L | 1500L | 2000L |
Ausgleichbehälter (Serienmäßig)(optional) |
50L | 75L | 100L | 150L | 200L | 300L | 300L | 400L | 550L | 800L | 1000L |
Kompressor | Standard: Dorin semi-closed compressor |
Standard: Hanbell screw compressor Optional: Bitzer screw compressor |
|||||||||
Control panel | 7 inch color touch screen display input, temperature curve record. | ||||||||||
Control System |
Standard: single chip microcomputer controller, position setting to open refrigeration and close refrigeration temperature difference. |
||||||||||
Optional: Siemens S7 series PLC and module. | |||||||||||
Geschlossenes System |
The whole system is fully closed system. The heat conduction medium does not absorb the water in the air and will be replenished automatically at low temperature. The system will not increase the pressure due to the high temperature in the operation. |
||||||||||
Umwälzpumpe | Wuxi guanya tube type centrifugal pump. | ||||||||||
Verdampfer | Standard: Brazing plate heat exchanger. | ||||||||||
Optional: stainless steel tube heat exchanger. | |||||||||||
Kühler | Shell and tube type water cooled condenser. | ||||||||||
Wärmetauscher | Plate heat exchanger. | ||||||||||
Trocknen Filter | Emerson | ||||||||||
Trocknen Der Filter | Emerson | ||||||||||
Expansion ventil | Emerson | ||||||||||
Die kühlung magnetventil | Emerson | ||||||||||
ölabscheider | Emerson | ||||||||||
Druck beschützer | Emerson | ||||||||||
Der akku | Standard:Ruishipu Optional: Emerson | ||||||||||
ALS flüssige Spiegel | Standard: Sanhua Optional: Danfoss | ||||||||||
Kälte - kugelventil | Standard: Sanhua Optional: Danfoss | ||||||||||
Elektrische | Schneider electric contact, schneider intermediate relay. | ||||||||||
Kältemittel | R404A | ||||||||||
Die Zweite kältemittel | Ethanol, dichloromethane, heat conduction medium, etc. | ||||||||||
Sicherheit |
High pressure protection, water break protection, current protection, leakage protection, continuous and broken phase protection, high temperature protection, sensor fault alarm, low level alarm and other multiple security protection. |
||||||||||
Ebene Indikator | Glass level indication | ||||||||||
Pipeline material | SUS304 | ||||||||||
Erweiterung material | SUS304 | ||||||||||
Shell Material | Channel steel + square pipe + cold rolled steel | ||||||||||
Netz spannung |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
380V 50HZ |
14kw | 18kw | 30kw | 43kw | 69kw | 101kw | 101kw | 200kw | 295kw | 396kw | 768kw | |
Shell Größe |
205*145 *175 |
205*145 *175 |
235*145 *175 |
300*150 *205 |
350*150 *205 |
350*180 *205 |
400*180 *205 |
450*180 *205 |
500*200 *225 |
550*220 *235 |
800*280 *255 |
Lärm | Within 75db | Within 80db | Within 90db |
Wir werden uns innerhalb von 24 Stunden bei Ihnen melden.