Model | GX-A028N | GX-A050N | GX-A0A10N | GY-A028N | GY-A050N | GY-A080N | GY-A0A16N |
Band | 280L | 500L | 1000L | 280L | 500L | 800L | 1600L |
Linien größe | 610*600*760 | 800*735*850 | 1000*1000*1000 | 800*600*600 | 1200*650*650 | 1350*800*750 | 2000*900*900 |
Die Tür Weise | (Vertical) | (Chest/Horizontal) | |||||
Tragende | 150KG | 220KG | 300KG | 150KG | 220KG | 300KG | 650KG |
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease) |
|||||||
Arbeits temp. bereich | -100℃~60℃ | -100℃~60℃ | -100℃~60℃ | -100℃~60℃ | -100℃~60℃ | -100℃~60℃ | -100℃~60℃ |
Kälte leistung | 0.7kw | 1 kw | 2 kw | 0.7kw | 1 kw | 2 kw | 3kw |
Präzision | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ | ±2℃ |
Heiz leistung | 2kw | 3kw | 5kw | 2kw | 3kw | 5kw | 8kw |
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection. |
|||||||
Abkühlung |
(Ambient temperature of 25℃, no-load, from 60 ℃s to -95 ℃ about 1 hour).;cooling rate will be a little different for temperature changes. |
||||||
Control System | ASET multifunctional controller | ||||||
Control panel | 7-inch color touch screen, display set temperature, measured temperature. | ||||||
Erfassung der Daten | Temperature curve and fault record, U-disk data export, excel format. | ||||||
Zirkulierende Winde | 1650 m³/h | 2100 m³/h | 2750 m³/h | 2100 m³/h | 2750 m³/h | 3500 m³/h | 6000 m³/h |
When it is open, the internal circulation fan automatically turns off. The touch screen displays open state. | |||||||
Kompressor | Emerson Copeland, adopt cascade refrigeration technology | ||||||
Die wärmetauscher | KAORI Plate heat exchanger | ||||||
Trocknen Filter | Emerson | ||||||
Expansion ventil | Electronic expansion valve | ||||||
Verdampfer | Copper-tube with aluminum-fin | ||||||
Die kühlung | Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30℃) | ||||||
Wärmedämmung | Polyurethane foam insulation, thermal insulation layer 125 mm, with embedded FIR boards | ||||||
Sicherheit |
Self-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection. |
||||||
Shell Material | Outside is cold rolled steel painting, internal is SUS304 wire drawing board. | ||||||
Kältemittel | R404A R23 R14 | ||||||
Shell Größe |
1150*1150 *1850 |
1350*1300 *1850 |
1550*1500 *2100 |
2200*1150 *1150 |
2700*1200 *1200 |
2900*1300 *1250 |
3700*1400 *1350 |
Netz spannung 380V 50HZ | 9KW MAX | 13.5KW MAX | 18KW MAX | 12KW MAX | 16.5KW MAX | 20KW MAX | 30KW MAX |
Gewicht | 470kg | 580kg | 750kg | 495kg | 625kg | 810kg | 940kg |
Auswahl |
High temperature reaches 150℃ and temperature accuracy is ±0.5℃;the input power will be changed (When select this model, the thickness of thermal insulation layer will be 150mm,thermal insulation material will be silicate and vacuum plate) |
||||||
Auswahl | Temp. accuracy ±0.5℃ | ||||||
Auswahl |
Cooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 45 steps.) |
||||||
Auswahl | Interior door, reduce cooling capacity lost when picking small workpieces (temperature below 60℃ optional) | ||||||
Auswahl | Outside SUS304 wire drawing board case | ||||||
Auswahl | Diameter 50mm cable hole | ||||||
Auswahl | Electric heating vacuum glass observation window (with lighting) 200mm*300mm | ||||||
Auswahl |
Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently) |
Wir werden uns innerhalb von 24 Stunden bei Ihnen melden.