Heat transfer oil circulation system refrigeration deterioration problem
I believe that many users have encountered the heat transfer oil circulation system after a long time of use, will feel the deterioration of the scene, LNEYA as a professional manufacturer to remind everyone, if you encounter these phenomena, users can find a professional manufacturer like LNEYA to buy or seek professional After-sales technical guidance to solve the problem.
Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user’s power supply and whether the equipment is normal. The test heat conduction oil circulation system is set to cool operation, and the working pressure is 4.5kg/cm2. Considering that the variable frequency heat transfer oil circulation system uses the electronic expansion valve to throttle, it is not accurate to judge the fault only by the working pressure. Therefore, the outdoor working current is measured again. The measurement finds that the working current is only 10.5A, which is much smaller than the rated value, and the fault is determined as “ Lack of refrigerant.”
Then, first find out the refrigerant leakage part of the heat transfer oil circulation system. Try to open the mechanism heat, use the washing spirit liquid to coat the joints for leak detection, and find that the joint is not tightened, which is the cause of refrigerant leakage. After tightening, check the leak again to make sure the pipeline is intact and then charge the system with refrigerant.
The heat transfer oil circulation system uses the “constant flow charging method”. In order to ensure the accuracy of the refrigerant charge, the exhaust pipe temperature sensor is first suspended. After starting up, use the ammeter to measure the current on the outdoor power line of the heat transfer oil circulation system. As the refrigerant replenishment increases, the current will gradually increase. When the rated current value reaches 12A (the 70-type inverter cabinet is 16A), the refrigeration The dosage of the agent is appropriate. This method is often used during home repairs.
If the heat transfer oil circulation system is overhauled or the leak is too large, and the refrigerant has leaked out in the system for a long time, the refrigerant can be charged by the quantitative method. First, the system is evacuated, and vacuuming or external air evacuation can be used. Then, the system is filled with refrigerant according to the standard. If the external air is emptied, it should be slightly less than the standard amount and in the cold state. These are the reasons why the heat transfer oil circulation system suddenly becomes uncooled or poorly cooled after several months of use.
LNEYA provides professional heat transfer oil circulation system, which is mainly engaged in professional brand equipment, with safe and reliable quality. If you need it, please come and purchase it.
Verwandte Empfehlungen
-
Was ist bei einem Wärmetauscher für den Wasserkreislauf zur Kühlung einer Autobatterie zu beachten?
1470The car battery cooling water circulation machine has always been one of the most popular equipments. The design of the heat exchanger piping also needs to be designed. What aspects should be considered? There are many types of heat exchange equip...
Details anzeigen -
Maintenance instructions for compressors at minus 85 degrees ultra low temperature freezer
1661The compressor in the ultra-low temperature freezer of minus 85 degrees is one of the main components, and its performance is very important, so maintenance is also very important. For manufacturers of sub-85 degree ultra-low temperature freezer c...
Details anzeigen -
LNEYA stellt auf der Achema 2018 aus
1196Die LNEYA Gruppe nimmt an der ACHEMA - Weltforum und Leitmesse für die Prozessindustrie in Frankfurt am Main teil und ist vom 11. bis 15. Juni 2018 an unserem Stand zu finden (detaillierte Informationen folgen),
Details anzeigen -
Semiconductor probe cooling chiller system
1600Semiconductor probe chiller, also known as semiconductor testing chiller or semiconductor testing cooling system, is a device designed to provide precise temperature control for semiconductor testing environments. It plays a crucial role in ...
Details anzeigen