Clean of Ultra-low Temperature Freezer
First wipe the machine shell from top to bottom with soapy water or disinfectant commonly used in the laboratory, then wipe it thoroughly with clean water, and dry it with a soft dry cloth.
Cautions: Avoid using too much water to clean the control board area, in order to prevent leakage damage of circuit components.
Cleanenvironment of ultra-lowtemperature freezer: Once a month
Clean up all ground debris and dust with sanitary ware, reduce dust adsorption in compressor and refrigeration system, affect heat dissipation
Prevent dust from adsorbing on circuit board, causing circuit components to be damaged by interference
Sealing test of door seals:
Once every six months, poor sealing will increase the working time of compressor and cause compressor failure.
Open the door, then put in a sheet of A4 paper, close the door, pull A4 paper out, if it is difficult to pull, it shows good sealing. It needs to be tested all around the door seal.
Clean air filter: Clean at least 4 times a year
Grasp the button at the bottom left corner and open the door directly below the cryogenic freezer.
Remove the black air filter and wash it with water or neutral detergent.
After drying, place the filter in place.
If it’s already dirty, the dust and debris on it can’t be removed, and a new filter needs to be replaced.
Clean condenser: at least twice a year
Refrigerator radiates heat to the outside environment through condenser.
Ash accumulation in condenser and filter will cause heat dissipation obstruction and decrease refrigeration efficiency of refrigerator.
1. Grasp the button at the bottom left corner and open the door directly below the refrigerator.
2. Use a vacuum cleaner to clean the dust on the condenser, or use compressed air to blow off the dust adsorbed on the condenser, or brush off the dust with a fine brush.
Notes: According to the environmental conditions of different laboratories, it is necessary to clean the condenser several times a year. And in the cleaning process, do not damage the radiator on the condenser.
Intracavity defrosting: once a year or when the thickness of defrosting exceeds 10 mm
High humidity, frequent door opening can easily lead to frost inside the door. Excessive frost, ice will affect the performance of refrigerators, can be deicing shovel and vacuum cleaner deicing.
1. Transfer samples from all chambers to another cryogenic refrigerator
2. Turn off the battery switch, the main power switch, and pull out the power cord.
3. Open all the inner doors and let the ice melt and wipe it off with a soft rag.
4. When the frost is removed, the inner cavity needs to be thoroughly cleaned with hot water or detergent (soda water) without chloride and wiped with a dry cloth.
5. Re-insert the power cord and turn on the main power switch and battery switch.
6. Samples can be placed after the refrigerator runs empty overnight.
We are a ultra low temperature freezer manufacturer. Welcome to choose our products.
Verwandte Empfehlungen
-
What Should Be Noticed In Detail When Installing A Precision Chiller?
1862First, when installation, everyone needs to check whether your cold water machine works normal, whether the accessories are all right, whether there is damage, so as to avoid problems in installation. Second, when installing, the site of the preci...
Details anzeigen -
Kaltwassersatz der Serie KRY für die Qualitätsprüfung von Fahrzeugen mit neuer Energie
1574The new energy vehicle powertrain test bench can be directly connected to the power output end of the electric drive assembly through the half-shaft. The front end is equipped with high-precision torque sensor and speed sensor to provide high-pre...
Details anzeigen -
Advantages of Industrial Chillers in Refrigeration
1690In recent years, the manufacturing industryhas entered a golden age. The market competition is fierce, and therequirements for product quality have been greatly improved. In fact, in theprocess of improving product quality, manufacturers oft...
Details anzeigen -
The use and characteristics of the SUNDI series of high and low temperature cooling circulators
1804The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant