The benefits of choosing a cryostat
The temperature of the effluent of the cryogenic refrigerator is very low, so the carrier medium can not be used for water (the water will freeze when it reaches 0 ° C). At this time, it is necessary to use a brine solution or a glycol solution, and the compressor to be used. Also, cryogenic refrigerators must use matched cryogenic compressors.
The cryogenic refrigerator can meet the needs of the user’s factory for sub-zero cryogenic fluids, so the whole machine function is very efficient because it has the following characteristics:
1. Stable performance, reliable quality, fast cooling speed, high efficiency, strong applicability, long service life, able to meet the factory’s 24-hour operation (if you need to stop, you must discharge the water/solution in the unit).
2. The refrigeration unit is compact in structure, and can be used as a box-sealed structural freezer according to the cooling power, or an open structure freezer. The bottom of some models of the box freezer is also equipped with casters, which is more convenient to install.
3. All low-temperature freezer has completed the debugging work before leaving the factory. Therefore, after receiving the user, the user can connect the equipments according to the installation diagram, and the power supply and water system can be put into use, which is convenient and quick.
4. The temperature control of the refrigeration unit can be adjusted by itself. According to the temperature requirements, the minimum temperature control of the unit is also different. If the minimum temperature is not required, the user can adjust the temperature on the control panel. For example, if you purchase a freezer, the temperature is -20 °C. If you don’t need it, you can adjust it to -15 °C, or -10 °C, but not more than -20 °C.
5. For low-temperature freezer with large cooling power demand, you can choose to use two or more compressors to make an independent refrigeration system. In the event of a compressor failure during the operation of the unit, other compressors can operate normally. This will not have a major impact on cooling demand. And in the process of repairing the faulty compressor, it does not affect the operation of other compressors.
The characteristics of the cryogenic refrigerator are clear. When choosing it, we must consider it clearly, especially its temperature requirements must be clear. After all, it is necessary to reach a temperature below zero. The lower the temperature, the more complicated the production. Only when the matching is reasonable can the cooling effect be better.
Verwandte Empfehlungen
-
Unterscheidung des Testsystems für die Integration von Strombatterien
2184Anhand des Überhitzungsgrades wird beurteilt, ob der Öffnungsgrad des integrierten Prüfsystems der Leistungsbatterie angemessen ist, und mit einem Thermometer wird die Differenz zwischen der Temperatur des Rücklaufs und der Verdampfungstemperatur gemessen...
Details anzeigen -
-
Wie reinigt man das Batteriekühlsystem von Fahrzeugen mit neuer Energie?
1360Das Batteriekühlsystem des neuen Energiemodells löst zunächst die drei Schrauben am oberen Teil des nassen Vorhangs, hält die Lamellen am oberen Teil des nassen Vorhangs fest, zieht den nassen Vorhang vorsichtig nach außen und hebt ihn dann leicht an, um ...
Details anzeigen -
Description of the principle and mode of industrial water chiller refrigeration cycle
2106Anyone who knows about industrial waterchillers should know that it uses compressors to achieve the cooling effect.So, how does it work when refrigerating?1. Vapor compression refrigeration cycle.After cooling and pressurizing the vaporfrom the...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant