How to install -50 °C cryogenic unit manufacturers equipment?
-50 °C cryogenic units are used in the refrigeration and chemical industry, so what issues should be paid attention to during installation? LNEYA professional manufacturers tell you that you should install according to the instruction manual.
For the -50 °C cryogenic unit compressor (unit) that has been tested at the factory and is protected by rust-proof seals and has good pre-installation protection measures, it can be directly installed, the protection measures are invalid, or the compressor (unit) has obvious defects. Check it and install it after confirming that it meets the factory manufacturer’s factory standards.
-50 °C cryogenic unit compressor (unit) should check the position of the foundation and anchor bolt holes before it is in place, it should meet the requirements of the design documents; it should be installed in the foundation and bracket according to the connection method required by the design and equipment technical documents. Welding shall not be used on hangers and on the design and equipment technical documentation. The installation should meet the requirements of the equipment technical documents. When leveling is required, the horn should be used. The installation should keep the body stable and should not exceed the inclination angle of the technical documentation of the equipment. Do not invert.
-50 °C cryogenic unit compressor (unit) manufacturer to ensure that the compressor does not corrode after leaving the factory and before use, no impurities, more inert gas for sealing treatment, so as long as the seal is intact, no obvious defects can be directly installation. For small, lightweight-50-degree cryogenic unit compressors (units), manual handling can be carried out during the installation process. Due to exceeding the limit angle or inversion, internal irreparable damage may occur, so standard handling is required. Refrigeration auxiliary equipment such as intercooler, gas-liquid separator, oil separator, liquid receiver, low-pressure circulating reservoir, oil collector, chiller, condenser, etc. in the refrigeration system shall be installed in accordance with current standards.
-50 °C cryogenic unit manufacturer Wuxi Guanya (LNEYA) will be arranged at the factory, the corresponding instructions to follow the equipment, the user can install according to the instructions.

Verwandte Empfehlungen
-
Cooling fin cleaning instructions for 20 freezers
1160As one of the main accessories of the 20-piece freezer, the heat-dissipating fins are very important. Therefore, the cleaning of the heat-dissipating fins is also very important. How to clean them? The fins of the freezer are also called finned co...
Details anzeigen -
Maintenance method of minus 17 ° C ultra-low temperature refrigerator
1018After the long-term use of the ultra-low temperature refrigerator of minus 17 °C, it is necessary to carry out certain maintenance work. If the user does not know how to carry out the maintenance work, you can contact the manufacturer to obtain th...
Details anzeigen -
Miniatur-Hochdruck-Reaktionskessel Kühlung Heizung Temperaturregelsystem
988Das Miniatur-Hochdruck-Reaktionskessel-Kühl-Heiz-Temperaturregelsystem ist mit einer Gaszufuhreinheit, einer Flüssigkeitszufuhreinheit, einer Reaktionseinheit und einer Sammeleinheit ausgestattet. Das Rohmaterialgas und die Rohmaterialflüssigkeit werden gemischt und...
Details anzeigen -
Übersicht über die Funktionsweise des LNEYA-Chip-Test-Temperaturkontrollsystems
1385Mit der Entwicklung der Technologie stellt die Chip-Prüfung sehr hohe Anforderungen an ihre Genauigkeit unter bestimmten Temperaturanforderungen. Was versteht man also unter dem Chiptestsystem? Chiptests erfordern eine hohe Temperaturgenauigkeit bei niedrigen Temperaturen...
Details anzeigen