Tipps für die tägliche Wartung von Ultra-Niedertemperatur-Rückkühlern?
To ensure normal operation of the ultra low temperature recirculating chillers after startup, it must be ensured that the condenser of the ultra low temperature recirculating chiller has good heat dissipation, otherwise the high temperature protection device of the ultra-low temperature circulating chiller will stop and even break down due to the condensing temperature and the corresponding condensing pressure, causing a malfunction. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, causing the cold water temperature protection device to stop and break down, or because the evaporation temperature and the corresponding evaporation pressure are too low, the low-pressure protection device of the chiller will stop and even cause the cold water in the evaporator freezes and damages the equipment.
1. In order to ensure the good performance of the unit, please keep the chiller in a good environment, with good ventilation and low temperature.
2. After turning off the compressor, turn off the cooling fan.
3. Every 6 months or when the performance of the chiller drops, please clean the condenser and check that the operating valve is in a normal state.
4. The optimum working pressure of the condenser should be less than 1.5MPa. Check and clean the condenser frequently to maintain the best performance of the machine.
5. For air-cooled machines, ensure that the machine is well ventilated and that the condenser is regularly maintained.
6. If it is not used for a long time, sometimes the pump impeller will be blocked by the sediment, so turn the pump cooling fan by hand before using the machine.
7. During the work, the parameters should be recorded in a timely and correct manner.
8. If there is an alarm stop during the operation, the relevant personnel should be notified in time to check the unit. If the fault cannot be eliminated, the factory can be directly contacted.
9. During the operation of the unit, it is strictly forbidden to short sub the water flow switch to avoid freezing the water pipe.
10. Machine rooms should be equipped with appropriate safety equipment and maintenance testing tools, such as pressure gauges, thermometers, etc., and the tools should be stored in a fixed position.
Verwandte Empfehlungen
-
Rangliste der Hoch- und Niedertemperatur-Kühl-Heiz-Wechselprüfkammern
1388Bei der Auswahl der Hoch- und Niedertemperatur-Kühl-Heiz-Wechselprüfkammer müssen die Unternehmensanwender ein gewisses Verständnis für die Rangliste der Hoch- und Niedertemperatur-Kühl-Heiz-Wechselprüfkammern auf dem Markt haben...
Details anzeigen -
Vocs gas condensing treatment equipment compressor maintenance instructions
1527The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
Details anzeigen -
LNEYA Wartungsanleitung für Kühlschränke mit geschlossenem Kreislauf
1586LNEYA geschlossenen Kreislauf Kühlschränke sollten beginnen, die Aufmerksamkeit auf ihre Wartungsarbeiten nach einer langen Zeit der Nutzung zu zahlen, dann, wie man Wartungsarbeiten durchführen? Wie führt man Wartungsarbeiten durch? Je nach der spezifischen Einsatzumgebung und der Häufigkeit der...
Details anzeigen -
Welches sind die Orte, die man für die Kühlung wählen sollte?
1860Today, with the development of science and technology, many customers focus on using high and low temperature to improve the quality of products and reduce the cost of products. So what are the places to pay attention to when choosing a model? Man...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant