How to deal with the excess refrigerant in 3p freezers?
When the three freezers are being serviced, it is necessary to add refrigerant regularly, but the manufacturer of LNEYA reminds everyone that once the refrigerant is added excessively, it will cause a series of problems.
According to the instructions of the 3p freezers, it is required to fill the refrigerant to maintain normal operation. If the number of refrigerants added by the company is very high during the operation of the 3p freezers, the higher the operating power, the stable operation of the equipment. The lower the sex, the more serious the failure of the equipment, the safety and stability of the equipment is directly endangered, and even the equipment can not meet the cooling demand of the space even if it consumes a lot of energy.
If the amount of refrigerant inside the three refrigerators is relatively large, while the equipment can be operated, although the temperature of the environment can be lowered in a short time, the running stability of the equipment is easily affected after the running time of the equipment increases. When the equipment can not run stably, the equipment often has some unexplained failures, endangering the service life of 3p freezers, and even causing equipment downtime, which seriously affects the normal use of the enterprise.
The maintenance of 3p freezers is not simple. Especially for the maintenance of the refrigeration system, even if the equipment is not faulty, in the case of normal use of the equipment, there will still be problems such as refrigerant leakage in the 3p freezers. The company can timely analyze whether the refrigerant has a leak failure, and keep the freezer within the normal pressure range, which can improve the operating efficiency of the three freezers. Even if the space used is very large, the equipment can also quickly reduce the ambient temperature and effectively meet the requirements. The low temperature demand of the enterprise provides conditions for improving the production efficiency of the enterprise.
If the refrigerant of 3p freezers is excessively added, it may cause more faults. Therefore, users should pay attention when adding refrigerants themselves, and try not to add excessive refrigerant, which causes the refrigerator to be unavailable and faults to occur.

Verwandte Empfehlungen
-
Umwelttechnische Beschreibung eines Kondensators für große industrielle Gefriergeräte
1080In industrial cold processing, large industrial freezers are one of the more used equipment. Among them, the condenser is one of the main components, and its performance is very important. Therefore, when choosing, everyone still needs to understa...
Details anzeigen -
Analyse von häufigen Fehlern im Batterietestsystem für New Energy Vehicle Power
943Wenn die neue Energie-Fahrzeug-Power-Batterie-Pack Lecks, die allgemeine Fehler Manifestation Modus: das Messgerät OK Licht nicht leuchtet, fordert das Messgerät, um das Stromnetz zu überprüfen, die Hochspannungs-System Leckage Fehler, trennen Sie die Batterie-Pack und die b...
Details anzeigen -
Wie lässt sich das Problem des Ausfalls der Umwälzpumpe der Kühlanlage lösen?
1061Kühlung Heizgeräte sind in vielen chemischen, pharmazeutischen und Laboranwendungen erforderlich. Dann, wie das Scheitern der Kühlung Heizung Gerät zu lösen ist auch besorgt über, wie es zu lösen? 1. Ausfall der Umwälzpumpe Die Umwälzpumpe...
Details anzeigen -
Collocation Requirements For Lab Water Chiller
1140The lab water chiller is a relatively advanced cryopreservation equipment, which is suitable for blood stations, hospitals, health and epidemic prevention systems, scientific research institutes, electronic industry, chemical medicine, biological ...
Details anzeigen