Beschreibung der Funktionsweise der Hoch- und Tieftemperatur-Schlagprüfkammer
Spot high and low temperature impact test chamber, also known as three-box high and low temperature impact test chamber, high and low temperature impact test chamber is mainly composed of low temperature storage chamber, high temperature storage chamber and impact temperature test chamber. Knowing how it works, plays a vital role in how to operate scientifically and how to protect it properly.
1. High-temperature storage room: The central controller detects the instantaneous signal from the temperature-sensing component, compares it with the set temperature signal, and obtains the comparison signal. The time-regulated heating of the solid-state relay is controlled by the output signal of the instrument PID logic circuit. The output power is sized to achieve automatic temperature control.
2. Low-temperature storage room: The temperature state of the spot high-low temperature impact test box is determined by the working state of the heater, evaporator and fan in the air duct. After the refrigerant flowing out through the expansion valve enters the evaporator in the working chamber, the heat in the working chamber is absorbed and vaporized, so that the temperature of the working chamber is lowered; the working fluid after gasification is sucked by the compressor and compressed into high temperature and high pressure gas into the condenser. The medium is condensed into a liquid, and after being screened, it is throttled by the expansion valve, and then again enters the evaporator of the working chamber to absorb heat and vaporize and then is sucked and compressed by the compressor. This reciprocating loop works to bring the studio temperature down to the set temperature requirement.
3. Impact temperature test room: Automatically control high and low temperature gas valve by spot high and low temperature impact test box instrument, switch between low temperature or high temperature storage room, form closed circuit air circulation system with high temperature box or low temperature box respectively, and quickly reach the test target temperature. The temperature state in the test chamber is determined by the operating conditions of the heater, evaporator, and fan in the duct. The working chamber of the test box adopts the forced axial flow “scattering” type loop wind operation, which can greatly improve the parameters such as fluctuation and uniformity of equipment operation.
After understanding the principle of use, the high and low temperature impact test chamber also needs regular maintenance to improve its efficiency.

Verwandte Empfehlungen
-
Precautions for Leakage Inspection of Glycol Chiller
1558The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, ...
Details anzeigen -
What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
1022Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when pur...
Details anzeigen -
What is the principle of industrial air-cooled chillers
1555Many industrial productions are inseparablefrom the low-temperature production environment provided by the chiller andcannot obtain efficient production capacity. Therefore, industrial chillerequipment is a very important refrigeration equipmen...
Details anzeigen -
Umwelttechnische Beschreibung eines Kondensators für große industrielle Gefriergeräte
1084In industrial cold processing, large industrial freezers are one of the more used equipment. Among them, the condenser is one of the main components, and its performance is very important. Therefore, when choosing, everyone still needs to understa...
Details anzeigen