Precautions For Compressor Installation of the Screw Chiller Factory
When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate circulation of air. The capacity of the ventilation and exhaust equipment must be greater than the exhaust volume of the compressor cooling fan, and the exhaust inlet position should be suitable for the hot exhaust outlet position of the compressor. Precautions for compressor installation of the screw chiller factory:
1. The compressor shall adopt a unit with large bearing capacity, and its operating speed and acceleration shall be limited within the permitted range.
2. Try to install the compressor of the screw chiller factory in a cool, clean and well-ventilated place to ensure that the air around the compressor is clean and the moisture content is minimized.
3. The air sucked by the compressor is not allowed to contain combustible gas and corrosive gas, so as not to cause internal explosion or internal embroidery.
4. Air-cooled machines should preferably have exhaust fans or air ducts to direct hot air out of the room to prevent hot air from circulating to the air inlet.
Commissioning of the new screw chiller factory shall be carried out by commissioning technicians designated or approved by the manufacturer. The compressor cannot work under the exhaust pressure higher than that specified on the nameplate, otherwise the motor will be overloaded and burnt out.
When the screw chiller factory is running, strictly check the running direction of the compressor. When reverse rotation is found, stop the machine immediately, cut off the power supply, switch any two of the three-phase lines, and restart the machine. Otherwise, the compressor of the screw chiller factory will be damaged (attention must be paid to each factory power supply overhaul!).
Verwandte Empfehlungen
-
Instructions for use of the enclosed cooling and heating circulator of LNEYA, a chiller manufacturer
904In the chemical and pharmaceutical field,the closed cooling and heating circulator is a cooling and heating temperaturecontrol device that cooperates with various types of reactors, jacketed tanks,reactors, extraction equipment and other equipm...
Details anzeigen -
Mit diesen Punkten kann die Nutzungseffizienz der Ultra-Niedrigtemperatur-Kältemaschine effizienter sein
1038The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
Details anzeigen -
What are the causes of corrosion in industrial chillers / water chillers?
1390Industrial chillers are now widely used in various industries, but as they become more and more widely used, many problems slowly emerge. Corrosion problems are also relatively common. Because everyone does not use the standard and the maintenance...
Details anzeigen -
LNEYA Hochtemperatur-Kühlschrank interne Leckage Problemlösung
1123Die Konfiguration von Hochtemperatur-Kühlschränken verschiedener Hersteller ist unterschiedlich. Die Konfiguration von Wuxi Guanya (LNEYA) Hochtemperatur-Kühlschränke ist alle von der Marke gekauft, mit einem vollständig geschlossenen Rohrleitungssystem, aber einige Manuf...
Details anzeigen