Small temperature control system equipment welding maintenance precautions
Small thermostat control system equipment pay attention to the point of comparison when repairing, LNEYA professional manufacturers reminded that the welding part is also one of the key points of maintenance, then what aspects should be paid attention to when welding?
When the small-scale thermostat control system equipment is welded, protective measures should be taken for the chassis and various components to prevent the flame from being burned by the torch. When welding, pay attention to the adjustment of the torch flame. When the flame is adjusted to the neutral flame, it can be welded. The speed should be as fast as possible to avoid damage to the compressor, the refrigeration valve body and the copper pipe.

If the copper tube is black after soldering, it should be adjusted to increase the flux flow until the copper tube is purple after soldering. When replacing the plate heat exchanger, the welding point should be soaked in water below the welding point, and the plate should be welded with a silver electrode containing 50% silver. It is forbidden to directly weld the plate heat exchanger without taking insulation measures, otherwise the temperature will be too high. After damage, after welding, it must be insulated with insulation board to prevent surface condensation. When installing, the inlet end is at the bottom and the outlet end is at the top.
The compressor of the small constant temperature control system equipment must not be placed horizontally or inverted during the handling of the compressor, otherwise the lubrication performance of the sliding part will be reduced and the compressor will be damaged when it starts. The inclination with respect to the horizontal state shall not exceed 5 degrees, and shall be welded into the system as soon as possible after the rubber stopper is removed, and the time is controlled within 10 minutes. When replacing the capillary, the length of the capillary cannot be increased or decreased arbitrarily, and when the length of the capillary is increased, an unfavorable situation will occur. When the copper tube and the capillary tube are connected, the capillary insertion depth is controlled to be about 10 mm, and the assembly gap of the copper tube brazing is 0.05 to 0.15 mm on one side.
The welded part is very important, and at the same time, it is necessary to pay attention to the strengthening of the process part. The welded part should be found by professional technicians for welding.
Verwandte Empfehlungen
-
Was sind die wichtigsten Punkte für die regelmäßige Wartung des Rückkühlers?
920Rückkühler werden in der Industrie häufig eingesetzt, und die wärmeerzeugenden Teile verschiedener Geräte erfordern Rückkühler, so dass die Betriebseffizienz sehr wichtig ist. Während der Betriebszeit des Rückkühlers ist es notwendig,...
Details anzeigen -
Drei häufige Ausfälle von luftgekühlten Schraubenkühlern
12831. Communication Failure: Computer-Controller steuert verschiedene Module durch Telekommunikationsleitungen und insgesamt Interface-Board, so dass die Hauptursache für die Kommunikation Fehler ist schlechter Kontakt oder Bruch der Kommunikationsleitungen, insbesondere die Schnittstelle oxida...
Details anzeigen -
Constant temperature circulation device can help chip to complete reliability test
938As the country vigorously develops domestic chips, chip manufacturing is entering the fast lane. After the chip is manufactured, there is a very critical link, which is the reliability test, and the constant temperature circulation device can quic...
Details anzeigen -
The Screw Chiller Factory With Noise Should Be Checked And Repaired In Time
988Before we use an industrial screw chiller factory, we will check all aspects of it, such as parts inspection, configuration, noise, and so on. What should I do if there is noise in the screw chiller during use? Do I need someone to repair it? The ...
Details anzeigen