Efficient operation of high and low temperature integrated machine
To ensure more efficient operation of the high and low temperature integrated machine, you should select the appropriate type of equipment and solve the problem in time.
The selection of high and low temperature integrated machines requires some process requirements of the screw type high and low temperature integrated machine, such as cooling effect, cooling capacity, power and refrigerant type. According to the cold load and application considerations, it is easy to adjust and save energy. It is preferred to use high-low temperature integrated machine with high performance coefficient, considering the factors such as water temperature and flow, inlet water temperature, flow rate and fouling coefficient.
The high and low temperature integrated machine has a high voltage failure, and the compressor discharge pressure is too high, resulting in the action of the high voltage protection relay. If the long-term pressure is too high, it will lead to excessive operating current of the compressor, easy to burn the motor, and easily cause damage to the valve port of the compressor exhaust port. The correct way should be to control the compressor discharge pressure within the safe range!
The high and low temperature integrated machine has a low valve temperature failure, and the outlet temperature of the expansion valve reflects the evaporation temperature, which is a factor affecting the heat exchange. Generally, it has a temperature difference of 5.0 to 6.0 ° C from the outlet water of the refrigerant water. When a low valve temperature fault occurs, the compressor will stop. When the valve temperature rises, it will automatically resume operation with a protection value of -2.0 °C.

The high and low temperature integrated machine compressor overheat fault, the thermistor is embedded in the compressor motor winding, and the resistance is generally 1kΩ. When the winding is overheated, the resistance value will increase rapidly. When the winding exceeds 141kΩ, the thermal protection module SSM will operate, the unit will be shut down, and the overheat fault will be displayed. The TH fault indicator will be on.
Low and low pressure integrated compressor low pressure fault compressor suction pressure is too low, resulting in low voltage protection relay action. If the suction pressure is low, the amount of return air is small, the cooling capacity is insufficient, and the electric energy is wasted. The heat of the compressor motor for return air cooling is poor, and the motor is easily damaged! The solution is the same as the high pressure fault, try to keep the compressor within the normal pressure range.
Understand the above phenomenon in order to operate better and more efficiently. LNEYA high and low temperature integrated machine adopts a fully closed circulation pipeline system. During operation, the pressure will not rise due to high temperature, and the low temperature will automatically replenish the heat transfer medium.
Verwandte Empfehlungen
-
500 liter reactor cooler selection instructions
1024The 500 liter reactor chiller is used more in the pharmaceutical industry. Therefore, the user needs to select a regular manufacturer when selecting, and at the same time, understand the features and configuration. For the selection of 500 liter r...
Details anzeigen -
Precautions For Compressor Installation of the Screw Chiller Factory
1087When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate ...
Details anzeigen -
Wartungsmethode für ein Ultra-Niedrigtemperatur-Kühlsystem (Kältesystem)
1026Die ultraniedrige Temperatur Kühler bezieht sich auf die Kühleinheit, deren gekühltes Wasser Temperatur erreicht unter minus 35℃. Das Gerät verwendet eine zweistufige Kompressionskühlung, und die Kombination aus Scrollverdichter und Kolbenverdichter wird...
Details anzeigen -
Cooling and heating temperature control equipment for liquid distribution system
862The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution s...
Details anzeigen