Die Analyse, wie man den Niedrigtemperatur-Zirkulator im täglichen Leben pflegt
Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extending the service life of heating cooling circulator at the most extent. In daily life, we should know about the maintenance method.
The manufacturers suggest that to check the fastening bolt of power wiring if it is loose, the normal status of high or low pressure value, and the running current or insulation resistant regularly.
It is important that if the device for drying and filtering of Heiz-Kühl-Umwälzpumpe and sight glass are running normally. If the exit frosts, it indicates the filter is blocked which needs clean filter; if the sight glass demonstrates the wetness ( it turns red), the core of device for drying and filtering wants to be changed.
It is vital that lubricating lube of heating cooling circulator compressor works. When operating, the fuel level is lower than two of thirds of oil sight glass, lubricant should be added; if there is foul or deterioration, lube should be replaced, and filter ought to be cleaned or changed; at the same time, filter core should be changed.
It is suggested that when heating cooling circulator has been used for a long time, conduction oil should be checked every three or six months, and the replacement is determined according to the practical situation. The heating cooling circulator of Guanya in Wuxi applies totally-enclosed circulation line where heat transfer oil will not be leaked or polluted. Pay attention to the replacement when foreign matter or water go into the oil box.
Please be informed by manufacturers that if the heating cooling circulator is not used for the time being, to clean the conduction oil left in the pipe, and to maintain and keep dry.
Verwandte Empfehlungen
-
How To Choose The Screw Type Water-Cooled Chiller
1893Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more. 1. The temperature of the heat conducting liquid can be adjusted to any temperature you want, a...
Details anzeigen -
Characteristics of the evaporator of LNEYA screw chiller
2305The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
Details anzeigen -
Wie geht man mit dem überschüssigen Kältemittel in 3p-Gefrierschränken um?
1711When the three freezers are being serviced, it is necessary to add refrigerant regularly, but the manufacturer of LNEYA reminds everyone that once the refrigerant is added excessively, it will cause a series of problems. According to the instructi...
Details anzeigen -
Wie man die Lebensdauer eines Glykol-Kühlsystems verlängert?
1533Um die Lebensdauer Ihres Glykolkühlers in industriellen Anwendungen zu verlängern, beachten Sie bitte folgende Punkte: 1. Verwenden Sie sorgfältig Frostschutzmittel in Automobilqualität Verwenden Sie kein Frostschutzmittel in Automobilqualität oder ungeeignetes Frostschutzmittel. Da diese Gl...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant