Kühleffekt einer wassergekühlten Kältemaschine bei -15℃
The main configurations of water-cooled
chillers are: compressors, electrical components, water pumps, evaporators,
condensers, high/low pressure controllers, high/low pressure gauges, LCD
thermostats, expansion valves, antifreeze switches, hand valves , Fan. Screw
chillers and high-precision constant temperature circulating chillers are
trusted by well-known international and domestic vacuum instruments, analytical
instruments, and other manufacturers.
Water circulation system of water-cooled
chiller:
First inject a certain amount of water into
the water tank of the chiller, cool the water through the chiller refrigeration
system, and then send the low-temperature cooling water to the equipment that
needs to be cooled by the water pump. The chilled water will take away the heat
and increase the temperature before returning to The water tank achieves the
cooling effect. The cooling water temperature can be automatically adjusted
according to requirements, and long-term use can save water. Therefore, the chiller
is a standard environmentally friendly and energy-saving equipment.
Refrigerant circulation system of
water-cooled chiller:
The liquid refrigerant in the evaporator
absorbs the heat in the water and starts to evaporate. Eventually, a certain
temperature difference is formed between the refrigerant and the water. The
liquid refrigerant is also completely evaporated and becomes a gaseous state,
which is sucked by the compressor and compressed (pressure and temperature
increase) , The gaseous refrigerant absorbs heat through the condenser
(air-cooled/water-cooled), condenses into a liquid, and is throttled by a
thermal expansion valve (or capillary tube) to become a low-temperature and
low-pressure refrigerant to enter the evaporator, completing the refrigerant
cycle process.
Features of water-cooled chillers
1. Fully enclosed refrigeration system,
stable work and reliable performance;
2. Digital display and control, high
temperature control accuracy and uniform temperature;
3. Using ultra-quiet circulating water
pump, the whole machine works quietly and has low noise;
4. High-performance refrigeration system
and pump circulation system, suitable for long-term continuous work;
5. Closed water tank and pipeline structure
to avoid coolant pollution and oxidation;
6. Standard stainless steel water inlet and
outlet ports, can be equipped with a variety of joints or hoses, external
closed loop;
7. Real-time display of working status and
alarm status;
8. Microcomputer temperature controller,
temperature digital display, adjustment unit 0.1 degrees Celsius, temperature
range 5~50 adjustable
9. The role of the mechanical industrial
equipment of the chiller: control the pressure oil temperature of the oil
pressure system, stabilize the oil temperature and oil pressure, extend the oil
quality use time, improve the efficiency of mechanical lubrication, and reduce
wear.
Multiple protections for water-cooled
chillers: 1. Over-temperature protection; 2. Current protection; 3.
Self-diagnosis; 4. Intelligent antifreeze; 5. Water flow alarm; 6. Water level
alarm; 7. Pressure alarm; 8. Time switch machine
LNEYA’s water-cooled chillers,
refrigeration circulators and other equipment can be customized in terms of
power, size and temperature range. For details, please contact sales@lneya.com
Verwandte Empfehlungen
-
Current status of hot and cold rapid temperature change test chamber
1615At present, manufacturers of hot and cold rapid temperature change test chambers are sprouting like spring bamboo shoots, but there are several manufacturers that really grasp the quality. When purchasing a test box, the buyer must first look at t...
Details anzeigen -
Organic waste gas treatment device noise description
2073With the increasingly stringent environmental requirements, various manufacturers have paid more and more attention to their own organic waste gas treatment. LNEYA organic waste gas treatment equipment specializes in the treatment of various organ...
Details anzeigen -
Vorsichtsmaßnahmen für die Platzierung von luftgekühlten Industriekühlern
2264The quality and use of industrial air cooled chillers are very important. At the same time, the user operation cannot ignore the position placement. Only the correct position placement and high-quality equipment can achieve high-efficiency operati...
Details anzeigen -
Ethylene glycol refrigeration unit made a strong attack and created LNEYA brand in 12 years
1974Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant