Air conditioning equipment that accurately controls ambient temperature and humidity, providing two equipment models, conventional water-cooled and mini air-cooled.

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 1)

Precision Temperature and humidity control unit (Water-cooled)

ModellLMW-01BSLMWX-01BSLMW-03BTLMWX-03BT
Rated Airflowm3/min0.7~1.02.0~4.0
Einstellbarer Temperatur- und Feuchtigkeitsbereich ℃/ %RH21~2621~26;45%RH~60%RH21~2621~26;45%RH~60%RH
Genauigkeit der Temperatur-/Feuchtigkeitsregelung℃/ %RH±0.1±0.1;±1.0%RH±0.1±0.1;±1.0%RH
Maximum Cooling Capacity(50/60Hz)KW0.2/0.250.37/0.451.31.3
Reheating Capacity(50/60Hz)KW0.1/0.130.40.50.7
Maximum Humidification CapacityKg/h/0.8/2.3
Humidification Water Supply Temperature Range/10~40/10~40
Humidification Makeup Water Pipe Connection//Rc1/2/Rc1/2
Humidification Makeup Water Pressurebar/0.3~2/0.3~2
Water Quality Requirement//

*Conductivity125~1250μs/cm     

*Water hardness not exceeding 40°f        

*Free of organic compounds

/

*Conductivity 125~1250μs/cm     

*Water hardness not exceeding 40°f         

*Free of organic compounds

Maximum External Static Pressure of Supply AirPa120/130120/160110/150110/150
Supply Air Outlet Connection Diametermmφ75φ100φ100φ100
Equipment Ambient Temperature℃/ %RH20~26;40%RH~60%RH ①
Ambient Temperature Accuracy Range℃/ %RH±1;±5%RH
StromversorgungV/Hz1~220v±10%; 50/60Hz±5Hz  3~380v±15%; 50Hz±5Hz  ④ 
Unit Rated Input PowerKW0.32/0.341.2/1.20.75  ⑤2.7 ⑤
Max Operating Current of UnitA1.7/1.82 6.4/6.4 1.354.8
Unit Noise Level(50/60Hz)dB(A)54/5658/606566
Max Input Power of UnitKWA0.34/0.38 1.5/1.5 1.44
Refrigerant/Charge QuantityKgR134A/0.13R407C/0.3R410A/0.4R410A/0.48
Unit N.WKg326995135
Unit G.WKg4085110150
Unit Overall Dimensions(L*B*H)mm500*412*346630*390*765 590*480*1070680*520*1350
Unit Packaging Dimensions (L*B*H)mm600*500*400750*500*850700*600*1200780*650*1400

Remarks:

1、The temperature and humidity control range does not necessarily represent the actual controllable range. The actual controllable temperature and humidity range is dependent on the inlet temperature and humidity, as well as the process air volume. Set the process air volume according to the operating environment.

2、For the M01/02 series, when the inlet temperature and humidity are stable, the accuracy values displayed on the controller apply only to a single point at the outlet and when operating at the maximum rated air volume.
For the M03 series, when running at the rated process air volume (3 m³/min), the temperature will fluctuate temporarily for approximately 2 minutes after start-up due to compressor oil backflow. Additionally, if the target humidity is high, and depending on the timing of humidification water supply, the previously mentioned accuracy may not be maintained. In such cases, adjusting parameters related to water supply can reduce the magnitude of fluctuations.
3、The constant static pressure at the air outlet on the outlet side of the supply fan when operating at the maximum rated process air volume.
4、Insert the product into a dedicated socket to prevent voltage drop. The phase unbalance of the three-phase power supply voltage should be less than ±3%.
5、When operating at the max working current within the specified range.。
6、Cooling water quality requirements: not lower than the “Design Code for Industrial Recirculating Cooling Water Treatment” GB50050-95; Note: 40°f is equivalent to 400ppm of CaCO₃. 7、Height includes the outlet end. The indicated values are when operating at the specified maximum humidification level. For possible details, refer to the operation manual.

Remarks: The supply air duct must be insulated, and the field installation should shorten the pipeline length as much as possible (max length shall not exceed 3m).

Precision Temperature and humidity control unit (Air-cooled)

Product ModelLW-0090-BW01LWX-0090-BW01LW-0100-BW01LWX-0100-BW01
Rated Airflowm3/h8000~9000 9000~10000  
Einstellbarer Temperatur- und Feuchtigkeitsbereich ℃/ %RH22~23;45%RH22~23;45%RH22~2322~23;45%RH~70%RH
Temp./Humidity Control Accuracy   ℃/ %RH±0.1±0.1;±1%RH±0.1±0.1;±1.0%RH
Max Cooling CapacityKW20kw @25℃16kw @26℃
Max Humidification CapacityKg/h/5/2.3
Outdoor Air Ratio  ② 20%20%//
Equipment Outdoor Air Temp & Humidity Range℃/ %RH23±2;;40%~60%±2%RH25; 50%RH
Equipment Return Air Temp & Humidity Range℃/ %RH23±0.1;45%RH ±2%RH/
Max External Static Pressure of Supply AirPa300~4000~200
Supply Air Outlet Connection Diametermmφ500φ500
Humidification Water Supply Temp Range/10~40/10~40
Humidification Makeup Water Pipe Connection//Rc1/2/Rc1/2
Humidification Makeup Water Pressurebar/1~4/1~4
Water Quality Requirement//

*Conductivity75~1250μs/cm      *Water hardness not exceeding 40°f         

*Free of organic compounds

/

*Conductivity 75~1250μs/cm      *Water hardness not exceeding 40°f        

*Free of organic compounds

Cooling Water Temperature18~2218~22
Cooling Water Connection G1″G1″
StromversorgungV/Hz3~380v±10%; 50Hz±5Hz  Three-phase five-wire system
Unit Rated Input PowerKW12.512.544
Maximum Operating Current of UnitA232377
Unit Noise LeveldB(A)≤80≤75
Maximum Input Power of UnitKWA158
Refrigerant/Charge QuantityKgR410A/4R410A/4
Safety Protection Functions Power overvoltage and undervoltage protection; phase reversal and loss protection; motor overheat and overload protection; compressor discharge temperature overheat protection; system high pressure protection; system low pressure protection; temperature module fault protection; adjustable over-temperature protection; fan motor overheat protection, etc.
Unit N.WKg750800650680
Unit G.WKg800850700750
Unit Overall Dimensions (L*B*H)mm2130*1000*20001200*1200*1950 
Unit Packaging Dimensions(L*B*H)mm2300*1150*21001350*1350*2050

Remarks:

1、The temperature and humidity control is applicable to different set temperatures, and can also operate steadily at a fixed operating temperature and humidity.

2、The unit can adjust a certain amount of outdoor air volume according to actual conditions to meet the HVAC outdoor air requirements.
3、Temperature and humidity range for outdoor and return air of the precision constant temperature and humidity unit.
4、The constant static pressure at the air outlet on the outlet side of the supply fan when operating at the maximum rated process air volume; it can also be adjusted according to whether the terminal is equipped with FFUs (Fan Filter Units). 5、440°f is equivalent to 400ppm of CaCO₃.
6、Cooling water quality requirements: not lower than the Design Code for Industrial Recirculating Cooling Water Treatment GB50050-95.
7、The supply air duct must be insulated, and the pipeline length should be shortened as much as possible during on-site installation. For detailed information, refer to the operation manual.

Der Schlüssel zur Gewährleistung hoher Präzision und hoher Effizienz

Environment Air Temperature Control Unit application scenarios


The equipment, production processes, inspection processes and spaces used in production facilities for equipment such as semiconductors, liquid crystals and solar panels require highly accurate and stable air processing.

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 2)

Fügen Sie unseren Account-Manager über den untenstehenden QR-Code hinzu

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 3)
<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 4)
<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 5)

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 6)

FLTZ 5℃~90℃
Prozesskühler

Kühlleistung 6kW~40kW
Kühlwasserfluss 1,5m³/h~9m³/h
Temperaturgenauigkeit ±0.05℃

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 7)

FLTZ -25℃~90℃
Thermische Kältemaschinen

Kühlleistung 2kW~15kW
Kühlwasserfluss 1,2m³/h~10,2m³/h
Temperaturgenauigkeit ±0.05℃

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 8)

FLTZ -45℃~90℃
Niedertemperaturkühler

Kühlleistung 1kW~8kW
Kühlwasserfluss 1,5m³/h~8m³/h
Temperaturgenauigkeit ±0.05℃

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 9)

FLTZ -80℃~+90℃
Umlaufwasserkühler

Kühlleistung 0,6kW~3kW
Kühlwasserfluss 1,8m³/h~6m³/h
Temperaturgenauigkeit ±0.05℃

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 10)

FLTZ -100℃~+90℃
Umlaufkühler

Kühlleistung 1,5kW~3kW
Kühlwasserfluss 50L/min~100L/min 2bar~7bar
Temperaturgenauigkeit ±0.05℃

warum wählen LNEYA?

❯Mehr als 15 Jahre Erfahrung in Konstruktion und Produktion
❯Rundum-Service
❯Kurze Lieferzeiten
❯Starker Kundendienst und technischer Support
❯Hochpräzise und wiederholbare Temperaturregelung
❯Hergestellt in Wuxi, China
❯Über 130 Patente

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 12)

Globaler Service

Mehr als 30.000 Kunden bedient.
Export in über 20 Länder.

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 13)

Zertifizierungspatente

Hat CE-Zertifizierung, SGS-Zertifizierung, ISO-Zertifizierung erhalten

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 14)

Kundendienst

Umfassende technische Schulungen anbieten.
Mit 24/7-Lösungen.

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 15)

Professionelles Team

Gegründet 2010, mit 15 Jahren Branchenerfahrung.
20 % der Mitarbeiter sind Techniker.

<trp-post-container data-trp-post-id='14913'>Precision air conditioner</trp-post-container>(images 16)

Qualitätskontrolle

Sichtprüfung.
Leistungstest.
Elektrische Sicherheitsprüfung.

*
*
*
Submissions in progress….
Einreichung erfolgreich!
Übermittlung fehlgeschlagen! Bitte versuchen Sie es später erneut
E-Mail-Fehler!
Falsche Rufnummer!