LTZ variable frequency belt heating function series, temperature control range: -40℃~+90℃, temperature control accuracy: ±0.3℃. The variable frequency unit adopts advanced variable frequency technology to accurately control the compression and fan operating speed, and quickly cools through intelligent adjustment of the electronic expansion valve.
Produktmerkmale
Produkt-Parameter
High efficiency and energy saving: The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user's cold and hot load requirements through the built-in variable frequency device, thereby avoiding the compressor and the full load of the electric heating to compete, maintain the stable working state of the unit, and achieve energy saving.
Rapid cooling: The variable frequency unit adopts advanced variable frequency technology to accurately control the compression and fan operating speed, and quickly cools through intelligent adjustment of the electronic expansion valve.
Ultra-low noise: The variable frequency unit adopts a variable frequency scroll or twin-rotor compressor, which greatly reduces the gyroscopic imbalance, making the vibration of the unit very small, about 1/2 of that of a conventional compressor, combined with multiple noise reduction measures, extremely quiet.
High environmental adaptability: The variable frequency unit adopts low frequency starting, small starting current, and small impact on the power grid. It has strong adaptability to voltage and can be started under a wide voltage range.
Long life: The variable frequency unit will not start and stop frequently, effectively reducing the loss of the unit when starting and stopping, and extending the life of the unit.
Modell | LTZ4-2H LTZ4-2WH |
LTZ4-4H LTZ4-4WH |
LTZ4-6H LTZ4-6WH |
LTZ4-10H LTZ4-10WH |
|
Temperaturbereich |
-40℃~90℃ |
||||
Genauigkeit der Temperaturregelung | PLC controller, control the water tank outlet temperature screen | ||||
Genauigkeit der Temperaturregelung | ±0.3℃ | ||||
Rückmeldung zur Temperatur | Temperaturrückführung PT100 (Eingangstemperatur, Ausgangstemperatur) | ||||
Heizleistung | 2,5 kW | 5,5 kW | 7,5 kW | 10kW | |
Kühlleistung | -15℃ | 2kW | 4,5 kW | 7kW | 11,5 kW |
-35℃ | 0.7kW | 1,5 kW | 2.3kW | 3,8 kW | |
Umwälzpumpe MAX | 20L/min 2bar | 35L/min 2bar | 50L/min 2bar | 100L/min 2bar | |
Kompressor | Famous brand compressor | ||||
Verdampfer | Plattenwärmetauscher | ||||
Bedienfeld | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
Schutz der Sicherheit | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||
Kältemittel | R-404A/R507C | ||||
Größe der Schnittstelle | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Strom | AC380V 50HZ/ AC460V 50HZ | ||||
Material der Schale | Cold rolled sheet (REL7035) | ||||
Kommunikationsprotokoll | Communication protocol MODBUS RTU protocol RS485 interface |
Modell | LTZ-2H LTZ-2WH |
LTZ-4H LTZ-4WH |
LTZ-6H LTZ-6WH |
LTZ-10H LTZ-10WH |
|
Temperaturbereich |
5℃~90℃ (Ethylene glycol water solution) |
||||
Genauigkeit der Temperaturregelung | PLC controller, control the water tank outlet temperature screen | ||||
Genauigkeit der Temperaturregelung | ±0.3℃ | ||||
Rückmeldung zur Temperatur | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||
Heizleistung | 3,5 kW | 5,5 kW | 7,5 kW | 15kW | |
Kühlleistung | 10℃ | 4kW | 8 kW | 12kW | 20kW |
Umwälzpumpe MAX | 20L/min 2bar | 35L/min 2bar | 50L/min 2bar | 100L/min 2bar | |
Kompressor | Famous brand compressor | ||||
Verdampfer | Plattenwärmetauscher | ||||
Bedienfeld | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||
Schutz der Sicherheit | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||
Kältemittel | R-134A / R407C | ||||
Größe der Schnittstelle | ZG3/4 | ZG3/4 | ZG1 | ZG1 | |
Strom | AC380V 50HZ/ AC460V 50HZ | ||||
Material der Schale | Cold rolled sheet (REL7035) | ||||
Kommunikationsprotokoll | Communication protocol MODBUS RTU protocol RS485 interface |
Warum sollten Sie sich für lneya als Ihren Lieferanten für Temperaturkontrolle entscheiden?
Jahre der Erfahrung
Zufriedene Kunden
m² Produktionsfläche
Patentierte Technologien
Besuch der LNEYA-Fabrik
Kontaktieren Sie uns
Schicken Sie uns Ihre Anfrage und wir werden Sie innerhalb von 24 Stunden kontaktieren.
Produkte empfehlen