WTD-Serie Kühl- und Heiztemperaturregelsystem für Mikrokanalreaktor
ANWENDUNGEN
Specially designed and developed for microchannel reactors with low liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system.Continuous high temperature cooling technology to meet the requirements of stable operation when hot and cold constant temperature control is required during high temperature exothermic reactions.
Produktmerkmale
Produkt-Parameter
Modell | WTD-120M | WTD-255 | WTD-455 | WTD-755 | WTD-275V | |
Temperaturbereich | -5°C~120°C | -25°C~200°C | -45°C~250°C | -70°C~200°C | -20°C~300°C | |
Temp accuracy | ±0.3℃ | |||||
Auflösung der Temperatur | 0.1K | |||||
Control panel | 7 inch colorful touch screen | |||||
Datenkurve | Data Curve Record | |||||
Date output | U disk excel format | |||||
Control model | PID Adaptive controller | |||||
Kommunikation | MODBUS RTU RS485 | |||||
Heizleistung | 2kW | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | |
Kühlleistung kW | 300°C | 7,5 kW | ||||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 7,5 kW | ||
100°C | 1,5 kW | 5,5 kW | 5 kW | 5 kW | 7,5 kW | |
20°C | 1 kW | 5,5 kW | 5 kW | 5 kW | 5,5 kW | |
-15°C | 2,5 kW | 4 kW | 4 kW | 2,5 kW | ||
-35°C | 1,5 kW | 3 kW | ||||
-60°C | 1.1kW | |||||
Umwälzpumpe max. | 7L/min 2.5bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | 25L/min 3bar | |
Größe der Verbindung | R1/2 | R3/4 | R3/4 | R3/4 | R3/4 | |
Temp sensor | PT100 | PT100 | PT100 | PT100 | PT100 | |
Kompressor | Emerson Copeland/Scope/Tecumseh | |||||
Verdampfer | Plattenwärmetauscher | |||||
Cooling way | Luftgekühlt | Air cooled+water cooled | ||||
Throttle type | Thermisches Expansionsventil | Electronic expansion valv | ||||
Trockener Filter | Danfoss | |||||
Heating-conduction medium | Synthetic heat conducting oil | |||||
Kältemittel | R404A | R404A | R404A | R404A R23 | R404A | |
Material der Rohre | SUS304 | SUS304 | SUS304 | SUS304 | SUS304 | |
Metal insulated hose | 1m*2 | 1.8M*2 | 1.8M*2 | 1.8M*2 | 1.8M*2 | |
Contactor/circuit breaker | Schneider | Schneider | Schneider | Schneider | Schneider | |
Abmessung cm | 35*56*75 | 55*70*175 | 55*70*175 | 65*85*185 | 55*70*175 | |
Gewicht kg | 60KG | 195KG | 205KG | 325KG | 245KG | |
Leistung 380V 50HZ | 220V 3.1kW | 9.5kW MAX | 10kW MAX | 12kW MAX | 15kW MAX | |
Material des Gehäuses | Cold rolled steel powder coating (standard color 7035) |
Modell | WTD-255-2T Double Temp range WTD-255W-2T Double Temp range |
WTD-455-2T Double Temp range WTD-455W-2T Double Temp range |
|||
Temperaturbereich | -25°C~200°C | -45°C~250°C | |||
Temp accuracy | ±0.3℃ | ||||
Auflösung der Temperatur | 0.1K | ||||
Control panel | 7 inch colorful touch screen | ||||
Datenkurve | Data Curve Record | ||||
Date output | U disk excel format | ||||
Control model | PID Adaptive controller | ||||
Heizleistung | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
Kühlleistung kW | 250°C | 5,5 kW | 5,5 kW | ||
200°C | 5,5 kW | 5,5 kW | 5,5 kW | 5,5 kW | |
100°C | 5kW | 5kW | 5 kW | 5kW | |
20°C | 5kW | 5kW | 5 kW | 5kW | |
-15°C | 2 kW | 2 kW | 4 kW | 4kW | |
-35°C | 1,5 kW | 1,5 kW | |||
Umwälzpumpe max. | 25L/min 3bar Double Line | 25L/min 3bar Double Line | |||
Größe der Verbindung | R3/4 Double Line | R3/4 Double Line | |||
Temp sensor | PT100 | PT100 | |||
Displays temp. data of two lines of inlet and outlet liquid | Displays temp. data of two lines of inlet and outlet liquid | ||||
Kompressor | Emerson Copeland | ||||
Verdampfer | Plattenwärmetauscher | Plattenwärmetauscher | |||
Cooling way | Air cooled + Water cooled | Air cooled + Water cooled | |||
Throttle type | Electronic expansion valv | Electronic expansion valv | |||
Trockener Filter | Danfoss | ||||
Heating-conduction medium | Synthetic heat conducting oil | ||||
Kältemittel | R404A | R404A | |||
Material der Rohre | SUS304 | SUS304 | |||
Metal insulated hose | 1.8M*4 | 1.8M*4 | |||
Contactor/circuit breaker | Schneider | Schneider | |||
Abmessung cm | 70*100*175 | 70*100*175 | |||
Gewicht kg | 325KG | 365KG | |||
Leistung 380V 50HZ | 19kW MAX | 20kW MAX | |||
Material des Gehäuses | Cold rolled steel powder coating (standard color 7035) |
Modell | WTD-2A38W-2TPEX | WTD-4A38W-2TPEX | WTD-7A50WPEX | |||
Temperaturbereich | -25~200°C | -25~200°C | -45~200°C | -45~200°C | -70~200°C | |
Temp accuracy | ±0.5℃ | |||||
Auflösung der Temperatur | 0.1K | |||||
Control panel | Explosionsgeschützter 7-Zoll-Farb-Touchscreen von Siemens | |||||
Datenkurve | Data Curve Record | |||||
Date output | U disk excel format | |||||
Kontrollsystem | Lneya Control System Siemens PLC | |||||
Systemumlaufflüssigkeit | 30L+30L | 30L+30L | 50L | |||
Volumen des Ausdehnungsgefäßes | 120L | 120L | 100L | |||
Heizleistung | 38kW | 38kW | 38kW | 38kW | 50kW | |
Heizgerät | Electric Heater Heating power 3W/cm2 | |||||
Heizungsaktor | Voltage regulating actuator 4~20mA control | |||||
Kühlleistung kW | 200°C | 38kW | 38kW | 38kW | 38kW | 50kW |
100°C | 38kW | 38kW | 38kW | 38kW | 50kW | |
20°C | 38kW | 38kW | 38kW | 38kW | 50kW | |
-15°C | 15kW | 15kW | 20kW | 20kW | 40kW | |
-35°C | 11kW | 11kW | 25kW | |||
-60°C | 12kW | |||||
Umwälzpumpe max. | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | |
Größe der Verbindung | DN50 PN16 | |||||
Wärmetauscher für Kühlwasser | Doppelrohr-Wärmetauscher | |||||
Kühlwassermenge | 25m³/h 1BAR~4bar max DN65 PN10 | 28m³/h 1BAR~4bar max 接口尺寸DN65 PN10 | 28m³/h1BAR~4bar max DN65 PN10 | |||
Kompressor | Emerson copeland scroll flexible compressor | |||||
Temp sensor | PT100 Fluid temperature of each group of inlet and outlet | |||||
Throttle type | Electronic expansion valv | |||||
Trockener Filter | Danfoss | |||||
Heating-conduction medium | Synthetisches Wärmeträgeröl | |||||
Material der Rohre | SUS304 | |||||
Elektrische Niederspannung | Schneider/Siemens | |||||
Abmessung cm | 250*200*220 | 250*200*220 | 250*200*220 | |||
Gewicht kg | 2500KG | 2600KG | 2600KG | |||
Leistung 380V 50HZ | 110kW MAX | 125kW MAX | 120kW MAX | |||
Explosionsgeschützte Form | Explosionssicherer Überdruck, Explosionssichere Produktinstallation Lizenz Nr. PCEC-2017-B025 | |||||
Material des Gehäuses | Cold rolled steel powder coating (standard color 7035) |
FUNKTIONSPRINZIP

Ultrahochtemperatur-Kühltechnologie kann direkt von einer hohen Temperatur von 300℃[kühlen, da nur das Wärmeübertragungsmedium in der Ausdehnungskammer mit dem Sauerstoff in der Luft in Berührung kommt (und die Temperatur des Ausdehnungsgefäßes zwischen Normaltemperatur und 60℃ liegt), was das Risiko der Oxidation des Wärmeübertragungsmediums und der Absorption von Wasser in der Luft verringern kann. Bei hoher Temperatur verdampft kein Wärmeübertragungsmedium, und eine kontinuierliche Temperaturregelung von - 80℃ ~ 190℃, - 70℃ ~ 220℃, - 88℃ ~ 170℃, - 55℃ ~ 250℃ und - 30℃ ~ 300℃ kann ohne Druckbeaufschlagung realisiert werden.
Color Screen Control

1. Zeigt alle Arten von Prozesskontrolltemperaturen an.
2. Zeigt den Flüssigkeitsstand des Wärmeleitmittels im Ausdehnungsgefäß an.
3. Zeigt an, dass das Kühlsystem funktioniert.
4. Zeigt an, dass die Heizung funktioniert.
5. Zeigt an, dass die Umwälzpumpe funktioniert.
6. Zeigt die Temperaturregelung an (Muster der Materialtemperaturregelung, Wärmeleitmitteltemperaturregelung).
7. Der obere und untere Grenzwert der Temperatur kann eingestellt werden.
8. Der Temperaturunterschied zwischen Mantel- und Reaktormaterial kann eingestellt werden.
9. Zeigt den Alarm zum Nachfüllen der Flüssigkeit an, wenn der Behälter leer ist.
10. Der Kühlkompressor kann auf manuellen oder automatischen Betrieb eingestellt werden.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
CUSTOM CHILLER TYPES
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
CUSTOM TEMPERATURE RANGES
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
CUSTOM CHILLER VOLTAGE
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
Besuch der LNEYA-Fabrik
Kontaktieren Sie uns
Schicken Sie uns Ihre Anfrage und wir werden Sie innerhalb von 24 Stunden kontaktieren.
Produkte empfehlen