Der Grund, warum der Kühlthermostat Chiller plötzlich nicht mehr startet

If there are any unexpected situations during the use of the cooling thermostat Chiller, it is important to promptly identify the specific reasons before resolving them, in order to effectively address various issues. For example, what is the reason why the cooling thermostat Chiller suddenly fails to start during operation?
One、 The reason why the cooling thermostat Chiller cannot start
1. The main reason is that during the operation of the system, the pressure at the equipment inlet is low, which cannot meet the basic operating conditions, leading to the problem of not being able to start.
2. According to the instructions for the configuration of the refrigeration thermostat Chiller, it can be understood that it is mainly caused by the idle water pump and other reasons. As long as the air in each system of the refrigeration thermostat Chiller is released, it can meet the suitable operating environment and achieve the purpose of starting the refrigeration thermostat Chiller.
3. The issue of stress. After experiencing varying degrees of startup difficulties, it is necessary to complete the maintenance of the refrigeration thermostat Chiller according to actual needs.
4. To ensure smooth operation, it is necessary to effectively control the inlet and outlet of the water pump during the use of the refrigeration thermostat Chiller. As the air is continuously eliminated, any malfunctions that cannot be started can be resolved.
Two、 Handling methods for encountering high-voltage faults
1. Due to insufficient cooling water flow, the rated water flow cannot be reached. The main manifestation is that the pressure difference between the inlet and outlet water of the unit decreases and the temperature difference increases. The reason for insufficient water flow is due to a lack of water or air in the system. The solution is to install an exhaust valve at a high position in the pipeline for exhaust; If the pipeline filter is blocked or too fine, and the permeability is limited, a suitable filter should be selected and the filter screen should be cleaned regularly; The selection of water pumps is relatively small and not compatible with the system. Excessive refrigerant charge.
2. This situation usually occurs after maintenance, manifested as high suction and exhaust pressure, balance pressure, and high operating current of the compressor. It should be deflated under rated operating conditions based on suction and exhaust pressure, balance pressure, and operating current until normal, so it is still necessary to regularly check.
Verwandte Empfehlungen
-
Influence of refrigeration factors on high temperature enclosed explosion-proof industrial chillers
1086Check whether the high and low temperature enclosed explosion-proof industrial chiller is the cause of its own failure. The selection must be accurate. If the model is not in place, the required refrigeration effect will also not be achieved. It i...
Details anzeigen -
What Industries Can Low Temp Chillers Help?
914Maybe some of you don't know much about low temp chiller products. The low temp chiller is a kind of professional refrigeration equipment used in industrial production. In recent years, there has been a great demand for different types of low temp...
Details anzeigen -
API China [A1A20-2] welcomes new and old customers!
1223API China, as a long-standing and large-scale exhibition in China's industrial field, has promoted and witnessed the development and growth of the pharmaceutical industry, and has also been accompanied by generations of Chinese pharmaceutical peop...
Details anzeigen -
Industrielle Anwendung von wassergekühlten Kaltwassersätzen
979Kältemaschinen, allgemein bekannt als Gefriergeräte, Kältemaschinen, Kältemaschinen, Kältemaschinen, Kältemaschinen usw., sind in verschiedenen Industriezweigen weit verbreitet, so dass die Namen zahlreich sind. Das Prinzip seiner Natur ist ein vielseitiges Kühlgerät, das Flüssigkeitsdampf durch ein Kom...
Details anzeigen