Welche Wartungsarbeiten sind bei Glykol-Kaltwassersätzen im täglichen Betrieb erforderlich?
In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance.
Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
Verwandte Empfehlungen
-
The reason why the semiconductor small thermostat is blocked by refrigeration
1189The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collect...
Details anzeigen -
LNEYA high and low temperature heating refrigerator maintenance instructions
1136High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high an...
Details anzeigen -
Reglerfunktion einer industriellen Kältemaschine
1349Bei der Verwendung von industriellen Kaltwassersätzen ist der Regler der wichtigste Punkt. Kennen Sie also die Funktion des Temperaturreglers des Kaltwassersatzes? Heute, wir werden darüber sprechen! 1. Der Strömungsschalter der Kältemaschine wird als Steuerung oder Unterbrechung verwendet...
Details anzeigen -
Description of compressors in various high and low temperature cycle machine industry
1193In the pharmaceutical and chemical industry, the application of high and low temperature cycle machine is relatively common. LNEYA high and low temperature cycle machine compressors use Emerson, Taikang, Duling and other brand compressors, but the...
Details anzeigen