Principle Analysis of Glycol Chiller
Glycol chiller is an industrial chiller
with glycol as refrigerant. The structure of glycol chiller is roughly the same
as that of ordinary industrial chiller, which is composed of compressor,
evaporator, condenser and electric control system. In order to ensure the
stable operation of glycol chiller, we suggest that you take explosion-proof
measures and buy explosion-proof glycol chiller as far as possible.
1、 Operation of compressor
In order to ensure that the pressure inside
the evaporator is low enough and that the refrigerant is at such a low
temperature, the compressor is used to extract the evaporated refrigerant and
compress the low temperature and low pressure into high temperature and high
pressure refrigerant gas.
2、 Use of condenser
High temperature and high pressure
refrigerant condenses into liquid in the condenser. The refrigerant in the
condenser releases heat in air or water lower than its temperature. Of course,
the temperature of air or water must be lower than that of refrigerant.
3、 How to throttle
After passing through the restrictor, the
refrigerant of the chiller drops from the condensation pressure to the
evaporation pressure, so the liquid from the condenser can be placed in the
liquid reservoir. At this time, the refrigerant is in the state of normal
temperature and high pressure, and then passes through the expansion valve to
reduce the boiling point, enters the evaporator, and the liquid absorbs heat
and evaporates.
4、 Endothermic evaporation
After passing through the restrictor, the
refrigerant liquid with low temperature and low pressure exchanges with the
evaporator, and the absorbed heat becomes saturated or superheated steam.
Verwandte Empfehlungen
-
Wie wählt man die Kältemaschine zur Kühlung des Mischtanks aus?
1151Mischbehälter werden in den Bereichen Beschichtungen, Medizin, Baustoffe, Chemikalien, Pigmente, Harze, Lebensmittel, wissenschaftliche Forschung und anderen Branchen zum Rühren, Mischen, Vermengen und Homogenisieren von Materialien verwendet. Der Mischbehälter erzeugt während des Mischvorgangs Wärme...
Details anzeigen -
Application of refrigeration and heating temperature control system in chemical synthesis
866chemical synthesis cooling heating system temperature control unit
Details anzeigen -
Integrated temperature control unit for reactors in pharmaceutical production
867The reactor system can effectively cooperate with the integrated temperature control system to meet the temperature control requirements of different chemical reactions and production processes. The reactor temperature control equipm...
Details anzeigen -
What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
1024Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when pur...
Details anzeigen