Welchen Einfluss haben die kältetechnischen Faktoren der geschlossenen explosionsgeschützten Kältemaschine?
Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when purchasing the enclosed explosion-proof chiller. The cooling capacity and other parameters are provided to the chiller manufacturer, and professionals will select the model for you to achieve the required cooling effect.
The enclosed explosion-proof chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor and indirectly affects the cooling effect. There is leakage or shortage of refrigerant in the enclosed explosion-proof chiller, which leads to a decline in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.
The dust in the condenser of the enclosed explosion-proof chiller will affect the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor cooling performance of the enclosed explosion-proof chiller. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and starts to evaporate. After the compressor is compressed and throttled by the expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the cooling effect.
When the filter of the enclosed explosion-proof chiller is blocked, it affects the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It needs to be checked regularly and cleaned. When the filter is seriously clogged, it is recommended to replace the new filter drier.
Verwandte Empfehlungen
-
Wie man die Lebensdauer eines Glykol-Kühlsystems verlängert?
1571Um die Lebensdauer Ihres Glykolkühlers in industriellen Anwendungen zu verlängern, beachten Sie bitte folgende Punkte: 1. Verwenden Sie sorgfältig Frostschutzmittel in Automobilqualität Verwenden Sie kein Frostschutzmittel in Automobilqualität oder ungeeignetes Frostschutzmittel. Da diese Gl...
Details anzeigen -
Wie behebt man den Ausfall der Kältemaschine für Materialalterungstests?
1738Regelmäßige Wartungsarbeiten für die Materialalterung Test Kühler, und Fehlersuche ist auch sehr wichtig. 1. Auspuff bei doppeltem Hochdruck, Wärmeableitung kann problematisch sein. Wenn festgestellt wird, dass die hohen und niedrigen Druck des Systems sind...
Details anzeigen -
LNEYA low temperature chiller selection classification description
2009Different enterprises and different industries have different requirements for the low-temperature chiller of Wuxi Guanya (LNEYA). The choice of models is also different, so it is better to understand them in the selection. The low temperature chi...
Details anzeigen -
Lneya’s high and low temperature cooling circulator instructions
1664The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according...
Details anzeigen
LNEYA Industriekühler Hersteller Lieferant