Basic structure manual of industrial chiller
Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories.
1. Verdichter: In industriellen Kältesystemen ist der Verdichter die Kraft, die für die Kühlung sorgt. Der Verdichter wird verwendet, um den Druck des Kältemittels im System zu erhöhen, so dass das Kältemittel in der Kälteanlage zirkulieren kann, um den Zweck der Kühlung zu erreichen.
2. Condenser: The high temperature and high pressure Freon of the refrigeration system enters the condenser after coming out of the compressor, releases a lot of heat to the cooling medium, and is then cooled and liquefied.
3. Evaporator: When the freon liquid in the refrigeration system enters the expansion valve for throttling and is sent to the evaporator, it belongs to the vaporization process. At this time, it needs to absorb a lot of heat, gradually reduce the valence and mass temperature, and achieve the effect of cooling.
4. Expansion valve: In the flow chart of the refrigerant system of the industrial chiller, we found that there is a small part between the condenser outlet and the evaporator inlet, which is called thermal expansion valve. It is a throttling and decompression component that reduces the condensing pressure of the refrigerant to the evaporating pressure. Therefore, its role in the refrigeration system is essential. It is connected with the refrigeration compressor, evaporator and condenser, also known as the four major components of the refrigeration system.
5. Other accessories: including drying filter and high and low pressure controller. The filter drier is not removable. The internal structure adopts molecular sieve structure, which can remove a small amount of impurities and moisture in the pipeline, thereby purifying the system. High and low pressure controllers play a protective role in the refrigeration system.
Verwandte Empfehlungen
-
Wie man das Problem löst, dass der 10-PS-Kühlschrank kein Wasser produzieren kann
1063Wuxi Guanya hat Kühlplatte Gefrierschrank zum Verkauf für die industrielle Kältebehandlung.Nun, wie das Problem der Wasserauslass Fehler von 10hp Kühlplatte Gefrierschrank zu lösen?Daher habe ich die entsprechenden Lösungen für die Wasserauslass Fehler von 10hp...
Details anzeigen -
Precautions for installing reactor refrigeration and heating cycle equipment
1454reactor temperature control unit installing
Details anzeigen -
The Role of Chemical Refrigeration Temperature Control Unit
1074In pharmaceutical and chemical plants, the raw materials inside the reactors involved in industrial production require rapid cooling and cooling. In order to achieve this goal, the reactor undergoes direct refrigeration and cooling, thereby indi...
Details anzeigen -
Main points of maintenance of flash high and low temperature test chiller
950Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional k...
Details anzeigen