Closed Refrigeration Heating Circulator Daily Maintenance Manual
The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life.
The user regularly maintains the closed refrigeration heating circulator, promptly eliminates the instrument failure, and makes maintenance records. The large equipment is cleaned and maintained 2-4 times per semester. The damaged closed refrigeration heating circulator should be overhauled by the equipment manufacturer’s professional. If external repair is required, the application should be submitted to the equipment. Equipment management personnel should strive to learn business and improve the level of management, maintenance and maintenance. Conduct regular inspections according to the specifications specified by the instrument or the performance indicators during commissioning, and register for future reference.
When the closed refrigeration heating circulator is turned on, it should be seen whether the steering of the fan is accurate. If the forward rotation can be started, the reverse rotation indicates that the power supply wiring is reversed, and the phase sequence must be replaced before starting. The setting values of each protection device are high and low temperature cycle. The factory has been set up, and users should not change it at will.
When the closed cooling and heating circulator is stopped, press the stop button to check the cause of the high fault. Do not force the machine to run before the fault is eliminated. If you use it for a long time in the winter, turn off the main power and drain the water in the system. It is necessary to keep the machine room clean and ventilated well, and carry out the cleaning and removing work of the condenser on schedule to ensure that the refrigeration and heating integrated machine does not work normally.
When using a closed refrigeration heating circulator, it is also necessary to pay attention to the selection of materials made of materials that are resistant to high temperature and corrosion resistant processes. In general, when using a closed refrigeration heating circulator, the temperature is in the range of 100 ° C – 300 ° C, the heating temperature is different, the oil used is also different, glycerin, paraffin oil, silicone oil, vacuum pump oil or some vegetable oil Yes, you can choose the right oil based on their heating temperature.
Closed refrigeration heating circulators provide corresponding cold sources in the pharmaceutical, chemical, biological and other industries. As a constant temperature source, the performance requirements are self-evident, so we must pay attention to the necessary maintenance.

Verwandte Empfehlungen
-
Battery test water cooler common knowledge description
1213Battery test Water-cooled air intake If there is no superheat, there may be a return air with liquid, and even cause a wet stroke liquid shock to damage the compressor. In order to avoid this phenomenon, a certain degree of suction superheat is re...
Details anzeigen -
What is the temperature of the cryogenic cooling circulator?
1000The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Details anzeigen -
How to choose a manufacturer with low failure rate 3p freezer?
948There are many factors in choosing a 3p freezer, and users should be cautious when choosing a manufacturer. Choose a 3p freezer with a low failure rate to reduce operating costs. When running a 3p freezer, the cost of using a 3p freezer will conti...
Details anzeigen -
Motor test bench test and temperature system for vehicle components
1332All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
Details anzeigen