Die Bedeutung der Niedrigtemperaturkammer
Die Tieftemperaturkammer ist eine große kryogene oder hochkryogene Prüfeinrichtung, die in der Regel den Kühlschrank vom Prüfling trennt und den Prüfling in eine Art Raum verwandelt, in dem das Personal arbeiten kann. Ein solcher Prüfraum wird als Tieftemperatur...
Die low temperature chamber usually adopts brick-wood structure or concrete structure, or steel structure, and its insulation layer is generally laid on the indoor side.
Low temperature environment will have a negative impact on the performance and reliability of machinery, vehicles, weapons, electronics and other equipment. It is the basic requirement for all kinds of ground equipment to be able to adapt to the low temperature environment that may occur in the use area. Before the development and finalization of all kinds of equipment, it is necessary to carry out low-temperature environmental test to test its adaptability to low-temperature environment.
The environmental laboratory is different from the environmental laboratory. It usually carries out the whole machine test, so its space is usually large, especially the large and medium-sized low temperature environment chamber. It must simulate the low temperature environment of – 60 ~50 C in a large space, so its investment and energy consumption are very large.
Cooling time is a basic parameter requirement of environment room. It is directly related to the installed capacity and investment of refrigeration system. Cooling time is shortened and the capacity and investment of refrigeration equipment will increase. In order to shorten the test preparation time, users often set a shorter cooling time. For large and medium-sized environment rooms, this will increase the investment of refrigeration system. How to reasonably determine the cooling time of cryogenic test is an urgent problem to be solved in the design of low temperature environment chamber.
Verwandte Empfehlungen
-
How to Control Static Electricity in Ultra-Low Temperature Test Chamber?
1002When using the ultra-low temperature test chamber, in order not to affect the quality of it, we need to better control static electricity. So how to control static electricity in Wuxi crown sub-cryogenic test chamber?Static electricity in the ultr...
Details anzeigen -
The Installation Requirement of the Industrial Chiller
986(1) The chiller power supply adopts three-phase four-wire, power supply line (R, S, T) connected with power supply fire line, (N) zero line, (G) ground line.,
Details anzeigen -
Mit diesen Punkten kann die Nutzungseffizienz der Ultra-Niedrigtemperatur-Kältemaschine effizienter sein
1056The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
Details anzeigen -
LNEYA star refrigeration heating system SUNDI-320/420W/430W
1206Today, I will introduce the model of LNEYA's refrigeration heating system: SUNDI-320/420W/430W. It has three kinds of medium temperature range: -30°C~180°C; -40°C~180°C; -40°C~200°C. The control system is programmed to program up to 10 programs...
Details anzeigen