Die Methode, die kleine wassergekühlte Kältemaschinen beim Befüllen mit Kältemittel befolgen müssen
In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, kleine wassergekühlte Kältemaschine is more common. This unit is composed of a compressor in the fuselage, a horizontal shell and tube condenser, an evaporator, a thermal expansion valve, and some related parts. Under the cooperation of these auxiliary parts, the overall small water cooled chiller is compact in structure, convenient in operation and control, and is popular among the public in the market.
For refrigeration systems that do not have a high pressure reservoir and a low pressure vapor-liquid separator, the control of refrigerant charge is particularly important. Because the refrigeration system is a condenser and also acts as a high-pressure reservoir, the refrigerant is stored in the condenser, and the condenser is cooled. The heat dissipation area is reduced and the condensing pressure is increased, resulting in a decrease in cooling capacity.
For the control of the refrigerant charge of such small water cooled chillers, the following methods are followed during the filling process:
First, touch the temperature of the condenser casing.
The upper outlet of the condenser outlet is heated above the outlet, and the outlet below the outlet is cool. (There is a description of the high temperature exhaust of the compressor in the inside. The cooling indicates that the small water-cooled chiller is a liquid space.)
Second, look at the inspiratory pressure.
Corresponding to the temperature of the refrigerant water in the evaporator. (That is, corresponding to the evaporation temperature.)
Third, look at the compressor return pipe temperature.
The high-temperature unit return pipe should be cooled and dew, but it can be dew condensation to the compressor return valve; the low-temperature unit return pipe should be frosted, but the frost can be connected to the compressor return valve. If condensation or frost builds up on the compressor casing, liquid refrigerant will enter the crankcase, causing the compressor to run back and cause liquid problem.
Verwandte Empfehlungen
-
The Phenomenon of Ice Jam in Low Temperature Chiller System
825The phenomenon of ice jam in low temperature chiller system is mainly due to the excessive water in the refrigeration system. With the continuous circulation of refrigerants, the water in the refrigeration system gradually concentrates at the outl...
Details anzeigen -
Auswahl eines Kühlbads und Wartungspunkte
1027Der so genannte Kältethermostat ist, wie der Name schon sagt, ein Gerät, das für eine konstante Temperatur sorgt. Im Allgemeinen spricht man auch von einem Brutkasten, einem Thermostat und so weiter. Man muss nur genug wissen, um das Kühlbad besser nutzen zu können. Kältethermostat...
Details anzeigen -
Beschreibung der Treiberchip-Stromversorgung im Chip-Test-Temperaturkontrollsystem
891Das Chip-Test-Temperaturkontrollsystem ist vor allem für die kalten Wärmequellen-Testgeräte für verschiedene Antriebschips gedacht. Vor dem Betrieb des Wuxi Guanya Chip-Test-Temperaturkontrollsystems muss der Benutzer die Leistung des Antriebschips kennen. I...
Details anzeigen -
Organic waste gas treatment device noise description
1369With the increasingly stringent environmental requirements, various manufacturers have paid more and more attention to their own organic waste gas treatment. LNEYA organic waste gas treatment equipment specializes in the treatment of various organ...
Details anzeigen