Vocs condensing separation equipment expansion valve maintenance instructions
Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs condensing separation device needs to be solved in time, and attention is paid to maintenance.
Before servicing the expansion valve, it is necessary to observe whether the expansion valve is normally closed. The ability to open and close the expansion valve in time means that the vocs condensing separation device is used normally, and can quickly reduce the ambient temperature in a short time. Conversely, if there is a fault in the expansion valve, then the pressure inside the vocs condensing separation device appears to be high or low. If the vocs condensing separation device expansion valve failure is not handled in time, the operational safety of the vocs condensing separation device will be affected, even jeopardized. To the company’s normal use of vocs condensation separation equipment.
In order to protect the vocs condensing separation equipment evaporator and expansion valve, in order to avoid the impact of the vocs condensing separation equipment operating power is affected, the company needs regular maintenance of the expansion valve and evaporator. It can eliminate the common faults of vocs condensation separation equipment in time, and clean up the surface and internal components of vocs condensation separation equipment, which can prolong the service life of vocs condensation separation equipment and create conditions for reducing the cost of vocs condensation separation equipment.
The vocs condensing separation equipment expansion valve blockage is a frequent occurrence, the main cause of dirty plugging is the presence of impurities in the system, such as welding slag, copper filings, iron filings, fibers and so on. The reason for ice blockage is that the system contains too much moisture (moisture). For light ice blockage, hot towel can be applied to the ice block. If the ice blockage is serious and has affected the normal operation of the system, it should be replaced. Filter the dryer, re-discharge the water in the system piping, evacuate, and refill the refrigerant.
It should be noted that the expansion valve of the vocs condensing separation equipment can be solved by contacting the vocs condensing separation equipment manufacturer if it cannot be solved during installation and maintenance.

Verwandte Empfehlungen
-
Warum brauchen Elektrounternehmen industrielle Kältemaschinen für Kühlsysteme?
907When electrical equipment is operating outdoors, it may encounter high temperature environments. For example, in direct sunlight in the summer, the temperature may be very high. If the equipment overheats, it will affect performance or even ...
Details anzeigen -
Product description for ultra-low temperature refrigeration
1029Technical parameters (low temperature cold storage project within 100 cubic meters) of Ultra-Low Temp Cold Storage 1. Medical cold storage temperature range(℃):Low-temperature storage library: -20°C to -50°C Preservation of plasma, biological ma...
Details anzeigen -
Directly at the exhibition | Shanghai Automotive Testing Expo
1253Application vehicle type:1. Hybrid electric vehicle; 2. Pure electric vehicle; 3. Hydrogen engine car; 4. Fuel cell electric vehicle; 5. Extended-range electric vehicle; 6. Other new energy vehicles;Application automotive field:It is specially d...
Details anzeigen -
Refrigeration Explanation for Screw Compressor of Low Temperature Chiller Circulator
1179Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the ...
Details anzeigen