Details der Schutzvorrichtung einer Vorrichtung zur Regelung der Temperatur einer zirkulierenden Flüssigkeit
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.

The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Verwandte Empfehlungen
-
Several elements of the operation of -20 degree industrial cryogenic chiller
1228-20 degree industrial cryogenic chiller is a refrigeration equipment that provides low temperature chilled water. It is often used in production enterprises, such as chemical companies, pharmaceutical companies and other production processes, to p...
Details anzeigen -
How to eliminate the failure of large thermal shock test chamber?
989As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner. A large t...
Details anzeigen -
Anleitung zur Auswahl eines Temperaturregelsystems für Halbleiterkühlgeräte
1368Die Wahl des Temperaturregelsystems für die Halbleiterkühlung sollte auf der Grundlage der Kühllast und der zu berücksichtigenden Faktoren erfolgen. Für Kältesysteme mit langen Betriebsbedingungen mit niedriger Last Betrieb, ist es geeignet, mul...
Details anzeigen -
Reglerfunktion einer industriellen Kältemaschine
1349Bei der Verwendung von industriellen Kaltwassersätzen ist der Regler der wichtigste Punkt. Kennen Sie also die Funktion des Temperaturreglers des Kaltwassersatzes? Heute, wir werden darüber sprechen! 1. Der Strömungsschalter der Kältemaschine wird als Steuerung oder Unterbrechung verwendet...
Details anzeigen