The reason why the semiconductor small thermostat is blocked by refrigeration
The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collects at the capillary outlet, in view of the relatively low temperature at the capillary outlet, the water It forms ice and gradually increases. When it reaches the necessary level, the capillary is completely blocked, the refrigerant does not recur, and the semiconductor small thermostat does not cool.
The main reason for the moisture in the small semiconductor small-scale thermostat refrigeration system is that the electromechanical insulation paper in the compressor contains water, which is the main source of moisture in the system. In addition, the residual moisture of the components of the refrigeration system and the combined pipelines due to insufficient drying; the refrigeration oil and the refrigerant contain more than the allowable amount of moisture; during the installation or maintenance process, the pipeline is in a state of development for a long time, causing moisture in the air to be Inhaled by electromechanical insulation paper and refrigerating machine oil.

In view of the fact that the above causes the water content of the refrigeration system to exceed the allowable amount of the refrigeration system, ice plugging occurs. On the one hand, ice plugs become refrigerants, and semiconductor small thermostats do not normally cool; on the other hand, water also reacts with refrigerants, synthesizes hydrochloric acid and hydrogen fluoride, and turns into corrosion of metal pipes and components. It will cause insulation damage of the electromechanical winding, and at the same time it will become the smell of the refrigerating machine oil, and the compressor will be smooth, so the water in the system is forced to operate at a relatively low limit.
The semiconductor small thermostat should try to avoid the blockage of its refrigeration system. If there is a blockage, it is also necessary to contact the technician to solve it in time.
Verwandte Empfehlungen
-
Wartungsschritte für die Hangheizung und -kühlung Kühlung Heizungsthermostat
974The slope temperature rise and fall cooling heating thermostat is the center to clean dust, garbage, etc. To clean and change inspection, inspection can find problems, find the potential defects of the slope temperature rise and fall high and low...
Details anzeigen -
5P Warm- und Kaltwassermaschine Installationsanleitung
1024The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
Details anzeigen -
Die Existenz der Destillation und die Temperaturkontrolle während der Destillation - SUNDI dynamic temp. control
970Destillation gibt es in Branchen wie der biopharmazeutischen und petrochemischen Industrie. Die Labordestillation umfasst die Vakuumdestillation, die Kurzwegdestillation, die Dünnschichtdestillation, die Wasserdampfdestillation, die Batch-Destillation, die azeotrope Dis...
Details anzeigen -
Which part of the chip testing system requires high and low temperature control?
788In the chip testing system, the environmental control equipment requires high and low temperature control. Specifically, this section mainly includes the following two key devices: 2. Temperature control system: For certain testing app...
Details anzeigen