Zusammenhang zwischen schlechter Kälteleistung und Kältemittel in der Niedertemperaturindustrie
The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are relatively low, and the expansion valve and the evaporator are in operation. The balance pressure cannot be maintained. Therefore, if the refrigerant leaks from the low-temperature industrial refrigerator (group) is found, it is not rushed to fill the system with the refrigerant. Instead, the leak point should be immediately found and the refrigerant should be filled after repair.
In the refrigeration system of the low-temperature industrial refrigerator (group), pay attention to the amount of refrigerant, too little, too much, too much, too much may cause the exhaust pressure of the low-temperature industrial refrigerator to rise, higher than the normal value, need to stop in time, use High pressure exhaust removes excess refrigerant from the system.
If the low-temperature industrial refrigerator (group) is filled with too much refrigerant after maintenance, the cooling effect will be worse, because the charge of the refrigerant will occupy a part of the condenser of the low-temperature industrial refrigerator (group), which is reduced. The cooling area and cooling efficiency are also decreasing, and the cooling rate is continuously decreasing. Therefore, according to the operation sequence, after the machine is shut down for a few minutes, excess refrigerant is released at the high pressure shut-off valve, and the residual air in the system can be released at the same time.
Of course, the refrigeration system inside the low-temperature industrial refrigerator (group) also needs to pay attention to, once the air in the low-temperature industrial freezer (group) refrigeration system will reduce the cooling efficiency, this time can be several times after a few minutes after the shutdown The high pressure shut-off valve releases air, and it is also possible to properly fill some refrigerant according to the actual situation.
The refrigeration effect of the low-temperature industrial refrigerator (group) is closely related to the amount of refrigerant. Therefore, users should pay attention to the refrigeration effect in time and strive for better operation of the low-temperature industrial refrigerator (group).
Verwandte Empfehlungen
-
The Advantage Parameter Explanation Of The Walk-In Lab Water Chiller
912In the experimental equipment, the walk-in lab water chiller is used for all kinds of electronic components in high and low temperature or hot and wet environment to test the requirements of various performance indicators. It is generally applicab...
Details anzeigen -
Kühl- und Heiztemperaturregelsystem zur Unterstützung der Temperaturregelung von Glasreaktoren
1042Die chemische Industrie meines Landes hat sich schnell entwickelt, und viele Unternehmen haben ihre stabile Entwicklung beschleunigt. In der chemischen Industrie wird das Kühl-Heizungs-Temperaturregelsystem mit einem Glasreaktor kombiniert, um den Rea...
Details anzeigen -
Zu beachtende Punkte bei der Auswahl von industriellen Heiz- und Kühlmaschinen
1086In Lebensmittelfabriken, pharmazeutischen Fabriken, in der Biologie, bei der Verarbeitung neuer Materialien und in Chemiewerken müssen die Rohstoffe im Reaktor während des industriellen Produktionsprozesses im Reaktor schnell abgekühlt werden. Um dies zu erreichen,...
Details anzeigen -
Micro-channel reactor thermostatically controlled air-cooled chiller compressor troubleshooting meth
1207The air-cooled chiller is a temperaturecontrol device that is widely used in the microchannel reactor industry. WuxiGuanya LNEYA has produced a cold and heat source thermostatically controlledair-cooled chiller for the microchannel reactor indu...
Details anzeigen