LNEYA data center liquid cooling solutionLiquid Cooled CDU Distribution Unit
Cold plate liquid cooling CDU-15kW
LNEYA relies on its strong R&D, construction, and operation and maintenance capabilities in the field of data centers to launch a cold-plate liquid-cooled CDU with a new air-liquid architecture. Building construction and renovation of old machine rooms, with excellent PUE indicators throughout the year, green, energy-saving, safe and reliable operation.

Applications: Renovation of small and medium-sized old data center
Energy saving, high efficiency and superior performance
Air-liquid structure, heat dissipation up to 12KW, green and energy-saving, system PUE≤1.2
Standard plug-in design, flexible layout, height is only 5U. Improve the rate of cabinets in the computer room
Front, side inlet, rear outlet air duct design, optimized airflow organization, cold and hot aisle isolation
Easy to install and easy to maintain
Does not involve the primary side pipeline layout, reducing the risk of pipeline laying, engineering quantity and water entering the machine room
Modular design, highly integrated products, easy installation, easy maintenance interface, standard quick connection, two-way cut-off of the flow channel, direct plug-in and maintenance of the pipeline on site
Renovation is simple. The old computer room can rely on the existing refrigeration system, only
Intelligent optimization of remote operation
System status analysis, real-time regulation of refrigerant flow, flow velocity and air volume, load balancing
Liquid product touch screen on-site and host computer remote centralized monitoring, human-computer interaction
Friendly interface
Anti-condensation control, liquid leakage detection, enhanced anti-interference design, high stability Support Modbus-RTUTCPMP communication
Safe and reliable system stability
Double-pump 2N redundant frequency conversion design, automatic switching in case of failure; when the two pumps are running at the same time, overclocking can increase the heat transfer by about 10%
Low-noise dual-fan design, when a single fan fails, the entire liquid cooling system will not stop
Expansion tank for pressure stabilization, full-scale group system design, leakage concealment reduction
High-efficiency pure copper micro-channel heat exchanger, highly compatible with pure steel liquid cold plate, improving system reliability
Introduction to cold plate liquid cooling system products and equipment
Introduction to cold plate liquid cooling chiller
Laden...
已经是到最后一篇内容了!
7 * 24 kostenlose Beratung und umfassende Lösungen anbieten


E-Mail: sales@cnzlj.com
WhatsApp: 086 13912479193
Verwandte Empfehlungen
-
Introduction to cold plate liquid cooling system products and equipment
1094Introduction to cold plate liquid cooling chiller
Details anzeigen -
Immersion phase change liquid cooling system
1116What is immersion phase change liquid cooling system?
Details anzeigen -
Semiconductor Testing Dual Channel heating Circulator Unit
784The dual channel heating cycler in semiconductor testing refers to a device used to test semiconductor devices (such as power semiconductors), which can simultaneously control two independent testing channels to perform heating and cooling...
Details anzeigen -
The main purpose of the ethylene glycol chiller for the heating and cooling unit of the reactor
1169The glycol chiller is suitable forhigh-purity metal, rare substance purification, laboratory environmentsimulation, magnetron sputtering, vacuum coating and other industries. Largecryogenic pump units can provide a cooling environment for labor...
Details anzeigen -
What should you pay attention to when using the cooling and heating oil bath?
946In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device? The cooling and heating oil bath equipment should be kept clean a...
Details anzeigen -
Wie lässt sich das Problem des Ausfalls der Umwälzpumpe der Kühlanlage lösen?
1067Kühlung Heizgeräte sind in vielen chemischen, pharmazeutischen und Laboranwendungen erforderlich. Dann, wie das Scheitern der Kühlung Heizung Gerät zu lösen ist auch besorgt über, wie es zu lösen? 1. Ausfall der Umwälzpumpe Die Umwälzpumpe...
Details anzeigen
Zur Konsultation einreichen
Wir werden Ihnen innerhalb von 24 Stunden antworten