Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Verflüssiger: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Verdampfer: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Ethernet-Schnittstelle TCP/IP-Protokoll
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
Die Pumpe mit variabler Frequenz kann den Druck und den Durchfluss des Hydraulikkreislaufs einstellen
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Verwandte Empfehlungen
-
Chip temperature control device selection instructions
1045With economic development and technological advancement, chip temperature control equipment has been developed by the chip industry. LNEYA, as a chip temperature control equipment manufacturer, also guarantees one of the performance and quality as...
Details anzeigen -
Basic structure manual of industrial chiller
1198Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
Details anzeigen -
Beschreibung der Eigenschaften von Kühlkörpern bei der Chip-Temperaturkontrolle
1272Mit der kontinuierlichen Entwicklung elektronischer Chips schreitet auch deren Wärmeableitungstechnologie voran. Die LNEYA Chip-Temperaturkontrolltechnologie wird zusammen mit den Chip-Testgeräten kontinuierlich gefördert. Der Entwicklungstrend der modernen Computerchips...
Details anzeigen -
Instructions On Refrigeration Of Low Temperature Chiller Circulating Machine Screw Compressor
1282Due to different compressors, the performance of low temperature chiller circulation machine is also different. Screw compressor is different from the piston compressor, whose structure is more sophisticated. Therefore, if the user needs to choose...
Details anzeigen